Literature DB >> 9402189

Simultaneous T2* and diffusion measurements with 3He.

M Bock1.   

Abstract

It has recently been demonstrated that magnetic resonance (MR) imaging of human lungs and airways is possible with hyperpolarized gases such as 3He. Because the influence of the apparent transversal relaxation (T2* decay) and diffusion in 3He imaging have not been quantified, an imaging pulse sequence was developed to measure these two parameters simultaneously. The imaging pulse sequence generates two series of multiply recalled gradient echo images with both different echo-spacings and diffusion-sensitizing gradients. From differences in exponential signal decay between the two series, T2* and diffusion coefficients, D, of both hyperpolarized and unpolarized 3He samples could be measured on a standard clinical imager using a home-built Helmholtz coil. In a hyperpolarized sample of pure 3He values of D = (1.8 +/- 0.2) x 10(-4) m2/s and T2* = 36 +/- 13 ms were measured, while D = (0.3 +/- 0.1) x 10(-4) m2/s and T2* = 136 +/- 66 ms were found in a Boltzmann-polarized 3He/O2 mixture.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9402189     DOI: 10.1002/mrm.1910380607

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Single-shot diffusion measurement in laser-polarized Gas.

Authors:  S Peled; C H Tseng; A A Sodickson; R W Mair; R L Walsworth; D G Cory
Journal:  J Magn Reson       Date:  1999-10       Impact factor: 2.229

2.  Probing lung microstructure with hyperpolarized 3He gradient echo MRI.

Authors:  Alexander L Sukstanskii; James D Quirk; Dmitriy A Yablonskiy
Journal:  NMR Biomed       Date:  2014-06-11       Impact factor: 4.044

3.  Assessment of the lung microstructure in patients with asthma using hyperpolarized 3He diffusion MRI at two time scales: comparison with healthy subjects and patients with COPD.

Authors:  Chengbo Wang; Talissa A Altes; John P Mugler; G Wilson Miller; Kai Ruppert; Jaime F Mata; Gordon D Cates; Larry Borish; Eduard E de Lange
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

Review 4.  Hyperpolarized 129Xe MRI of the human lung.

Authors:  John P Mugler; Talissa A Altes
Journal:  J Magn Reson Imaging       Date:  2013-02       Impact factor: 4.813

5.  Compressing Spin-Polarized (3)He With a Modified Diaphragm Pump.

Authors:  T R Gentile; D R Rich; A K Thompson; W M Snow; G L Jones
Journal:  J Res Natl Inst Stand Technol       Date:  2001-08-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.