Literature DB >> 9400864

Breath-hold R2* mapping with a multiple gradient-recalled echo sequence: application to the evaluation of intrarenal oxygenation.

P V Prasad1, Q Chen, J W Goldfarb, F H Epstein, R R Edelman.   

Abstract

Blood oxygenation level dependent (BOLD) MRI is sensitive to changes in regional oxygen supply versus demand and is therefore potentially useful in evaluating susceptibility to ischemic injury. Recently, we have demonstrated the use of BOLD MRI to evaluate intrarenal oxygenation using single shot echo-planar imaging (EPI). Here, we present an alternate implementation of BOLD MRI sequence, using multiple gradient echoes, that does not require any specialized hardware.

Entities:  

Mesh:

Year:  1997        PMID: 9400864     DOI: 10.1002/jmri.1880070633

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  22 in total

1.  Evaluation of changes in intrarenal oxygenation in rats using multiple gradient-recalled echo (mGRE) sequence.

Authors:  A Priatna; F H Epstein; K Spokes; P V Prasad
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

Review 2.  Noncontrast functional MRI of the kidneys.

Authors:  Lorenzo Mannelli; Jeffrey H Maki; Sherif F Osman; Hersh Chandarana; David J Lomas; William P Shuman; Ken F Linnau; Douglas E Green; Giacomo Laffi; Miriam Moshiri
Journal:  Curr Urol Rep       Date:  2012-02       Impact factor: 3.092

Review 3.  MR urography in children.

Authors:  J Damien Grattan-Smith; Richard A Jones
Journal:  Pediatr Radiol       Date:  2006-06-22

4.  Evaluation of intrarenal oxygenation by BOLD MRI at 3.0 T.

Authors:  Lu-Ping Li; Anthony T Vu; Belinda S Y Li; Eugene Dunkle; Pottumarthi V Prasad
Journal:  J Magn Reson Imaging       Date:  2004-11       Impact factor: 4.813

5.  Changes in intrarenal oxygenation as evaluated by BOLD MRI in a rat kidney model for radiocontrast nephropathy.

Authors:  P V Prasad; A Priatna; K Spokes; F H Epstein
Journal:  J Magn Reson Imaging       Date:  2001-05       Impact factor: 4.813

6.  Changes in renal medullary pO2 during water diuresis as evaluated by blood oxygenation level-dependent magnetic resonance imaging: effects of aging and cyclooxygenase inhibition.

Authors:  P V Prasad; F H Epstein
Journal:  Kidney Int       Date:  1999-01       Impact factor: 10.612

7.  GESFIDE-PROPELLER approach for simultaneous R2 and R2* measurements in the abdomen.

Authors:  Ning Jin; Yang Guo; Zhuoli Zhang; Longjiang Zhang; Guangming Lu; Andrew C Larson
Journal:  Magn Reson Imaging       Date:  2013-09-14       Impact factor: 2.546

8.  Evaluation of the reproducibility of intrarenal R2* and DeltaR2* measurements following administration of furosemide and during waterload.

Authors:  Lu-Ping Li; Pippa Storey; Linda Pierchala; Wei Li; Jason Polzin; Pottumarthi Prasad
Journal:  J Magn Reson Imaging       Date:  2004-05       Impact factor: 4.813

9.  Early changes with diabetes in renal medullary hemodynamics as evaluated by fiberoptic probes and BOLD magnetic resonance imaging.

Authors:  Elisabete Alcantara dos Santos; Lu-Ping Li; Lin Ji; Pottumarthi Vara Prasad
Journal:  Invest Radiol       Date:  2007-03       Impact factor: 6.016

Review 10.  Blood oxygen level-dependent MR imaging of the kidneys.

Authors:  Lu-Ping Li; Sarah Halter; Pottumarthi V Prasad
Journal:  Magn Reson Imaging Clin N Am       Date:  2008-11       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.