Literature DB >> 9399517

Evaluation of the BBL Crystal Anaerobe identification system.

J J Cavallaro1, L S Wiggs, J M Miller.   

Abstract

The BBL Crystal Anaerobe (ANR) identification system was evaluated, and the results were compared with those from conventional anaerobic methods. We tested 322 clinically significant anaerobic bacteria according to the manufacturer's instructions. The system identified correctly 286 of 322 (88.8%) of the anaerobic bacteria tested. Of these, 263 of 322 (81.7%) were identified correctly on initial testing and 49 were identified correctly only to the genus level; on repeat testing, 23 of 49 (46.9%) were identified correctly to both the genus and the species levels. A total of 26 (8.5%) were misidentified at the species level, and 10 (3.1%) were not identified. Performance characteristics for individual strains varied. The system correctly identified all tested strains of Campylobacter, Desulfomonas, Desulfovibrio, Leptotrichia, Mobiluncus, Peptostreptococcus, Porphyromonas, Provetella, Propionibacterium, Tisierella, and Veillonella and 36 of 37 (97.3%) Actinomyces strains, 42 of 46 (91.3%) B. fragilis group strains, 79 of 103 (76.7%) Clostridium strains, (however, the system failed to identify any of the 7 C. innocuum and 9 C. tetani strains tested), and 8 of 15 (53.3%) Bacteroides strains. This system was easy to use, did not involve the addition of reagents, and was faster than conventional anaerobic procedures. It would be a useful addition to the anaerobe laboratory of most hospitals.

Entities:  

Mesh:

Year:  1997        PMID: 9399517      PMCID: PMC230145          DOI: 10.1128/jcm.35.12.3186-3191.1997

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Evaluation of the new RapID-ANA II system for the identification of clinical anaerobic isolates.

Authors:  L M Marler; J A Siders; L C Wolters; Y Pettigrew; B L Skitt; S D Allen
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

2.  Clinical evaluation of the RapID-ANA II panel for identification of anaerobic bacteria.

Authors:  D M Celig; P C Schreckenberger
Journal:  J Clin Microbiol       Date:  1991-03       Impact factor: 5.948

Review 3.  Fluorogenic and chromogenic substrates used in bacterial diagnostics.

Authors:  M Manafi; W Kneifel; S Bascomb
Journal:  Microbiol Rev       Date:  1991-09

4.  Anaerobic bacteria. Their role in infection and their management.

Authors:  S M Finegold
Journal:  Postgrad Med       Date:  1987-06       Impact factor: 3.840

5.  Evaluation of the AnIdent system for the identification of anaerobic bacteria.

Authors:  M J Stenson; D T Lee; J E Rosenblatt; J M Contezac
Journal:  Diagn Microbiol Infect Dis       Date:  1986-05       Impact factor: 2.803

6.  Comparison of the PRAS II, AN-Ident, and RapID-ANA systems for identification of anaerobic bacteria.

Authors:  R S Burlage; P D Ellner
Journal:  J Clin Microbiol       Date:  1985-07       Impact factor: 5.948

7.  Evaluation of API An-IDENT and RapID ANA II systems for identification of Actinomyces species from clinical specimens.

Authors:  P H Miller; L S Wiggs; J M Miller
Journal:  J Clin Microbiol       Date:  1995-02       Impact factor: 5.948

8.  Rapid enzymatic characterization of clinically encountered anaerobic bacteria with the API ZYM system.

Authors:  L Marler; S Allen; J Siders
Journal:  Eur J Clin Microbiol       Date:  1984-08       Impact factor: 3.267

9.  Comparison of Minitek Anaerobe II, API An-Ident, and RapID ANA systems for identification of Clostridium difficile.

Authors:  G Bate
Journal:  Am J Clin Pathol       Date:  1986-06       Impact factor: 2.493

10.  Evaluation of the RapID ANA II and API ZYM systems for identification of Actinomyces species from clinical specimens.

Authors:  M A Brander; H R Jousimies-Somer
Journal:  J Clin Microbiol       Date:  1992-12       Impact factor: 5.948

View more
  6 in total

1.  Evaluation of four commercial test systems for identification of actinomyces and some closely related species.

Authors:  Anne-Marie Santala; Nanna Sarkonen; Val Hall; Petteri Carlson; Hannele Jousimies-Somer; Eija Könönen
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

2.  Empyema caused by Anaeroglobus geminates, a case report with literature review.

Authors:  C-H Wang; L-P Kan; J-R Sun; C-M Yu; T Yin; T-W Huang; W-C Tsai; Y-S Yang
Journal:  Infection       Date:  2014-08-26       Impact factor: 3.553

3.  Evaluation of the new Vitek 2 ANC card for identification of medically relevant anaerobic bacteria.

Authors:  Francine Mory; Corentine Alauzet; Céline Matuszeswski; Philippe Riegel; Alain Lozniewski
Journal:  J Clin Microbiol       Date:  2009-04-22       Impact factor: 5.948

4.  Evaluation of the Vitek 2 ANC card for identification of clinical isolates of anaerobic bacteria.

Authors:  E H L Lee; J E Degener; G W Welling; A C M Veloo
Journal:  J Clin Microbiol       Date:  2011-03-16       Impact factor: 5.948

5.  PCR assay for species-specific identification of Bacteroides thetaiotaomicron.

Authors:  L J Teng; P R Hsueh; J C Tsai; F L Chiang; C Y Chen; S W Ho; K T Luh
Journal:  J Clin Microbiol       Date:  2000-04       Impact factor: 5.948

6.  Biochemical differentiation and comparison of Desulfovibrio species and other phenotypically similar genera.

Authors:  Yumi A Warren; Diane M Citron; C Vreni Merriam; Ellie J C Goldstein
Journal:  J Clin Microbiol       Date:  2005-08       Impact factor: 5.948

  6 in total