Prospective randomized trial of a metallic intravascular stent in hemodialysis graft maintenance.

E K Hoffer1, S Sultan, M M Herskowitz, I D Daniels, S J Sclafani.   

Abstract

PURPOSE: To evaluate percutaneous transluminal angioplasty (PTA) alone versus PTA and flexible self-expanding stent placement for the management of hemodialysis access graft stenoses.
MATERIALS AND METHODS: Thirty-seven grafts in 34 patients were evaluated for abnormal intradialytic parameters (n = 27) or occlusion (n = 10). Angiography identified stenoses (mean, 69%; range, 50%-95%) at or within 3 cm of the vein-graft junction (70%) or in the peripheral outflow vein (30%) that had recurred within a 6-month period after previous PTA. They were randomized to PTA alone (n = 20) or PTA with Wallstent (n = 17). Additional lesions were treated by PTA alone, and a mean of 1.4 (range, 1-3) lesions were treated per patient. Significant differences existed in the mean number of previous accesses (1.8 and 0.8 in the PTA and stent groups, respectively) and in the mean number of previous interventions in the current access (1.8 and 2.9, respectively). End points were subsequent radiologic or surgical intervention, transplantation, and death.
RESULTS: Technical success was 100% (mean residual stenosis, 12%; range, 0%-30%). The primary patency of 128 days and secondary patency of 431 days were similar for both groups. Secondary patency required a mean of 1.8 and 1.6 additional interventions for the PTA and stent groups, respectively. The adjunctive stent placement increased the cost of the procedure by 90%.
CONCLUSION: Despite significant added costs, there was no advantage to stent placement for recurrent peripheral hemodialysis graft stenoses that were already adequately dilated with balloon angioplasty.

Entities:  

Mesh:

Year:  1997        PMID: 9399465     DOI: 10.1016/s1051-0443(97)70695-x

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  15 in total

Review 1.  A practical review of the use of stents for the maintenance of hemodialysis access.

Authors:  Michael Ginsburg; Jonathan M Lorenz; Sean P Zivin; Steven Zangan; Don Martinez
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

Review 2.  Stent and Stent-Graft Use in Arteriovenous Dialysis Access.

Authors:  Gordon McLennan
Journal:  Semin Intervent Radiol       Date:  2016-03       Impact factor: 1.513

Review 3.  Advanced Stent Graft Treatment of Venous Stenosis Affecting Hemodialysis Vascular Access: Case Illustrations.

Authors:  Darshan Patel; Charles E Ray; R Peter Lokken; James T Bui; Andrew J Lipnik; Ron C Gaba
Journal:  Semin Intervent Radiol       Date:  2016-03       Impact factor: 1.513

4.  Treatment of failing arterio-venous dialysis graft by angioplasty, stent, and stent graft: Two-years analysis of patency rates and cost-effectiveness.

Authors:  Jan Kavan; Jaroslav Kudlicka; Jan Malik; Eva Chytilova; Lukas Lambert; Marcela Slavikova; Patrik Matras; Andrea Burgetova
Journal:  Exp Ther Med       Date:  2019-09-25       Impact factor: 2.447

5.  Use of stents for the maintenance of hemodialysis access.

Authors:  Jonathan M Lorenz
Journal:  Semin Intervent Radiol       Date:  2004-06       Impact factor: 1.513

Review 6.  Definitions and End Points for Interventional Studies for Arteriovenous Dialysis Access.

Authors:  Gerald A Beathard; Charmaine E Lok; Marc H Glickman; Ahmed A Al-Jaishi; Donna Bednarski; David L Cull; Jeffery H Lawson; Timmy C Lee; Vandana D Niyyar; Donna Syracuse; Scott O Trerotola; Prabir Roy-Chaudhury; Surendra Shenoy; Margo Underwood; Haimanot Wasse; Karen Woo; Theodore H Yuo; Thomas S Huber
Journal:  Clin J Am Soc Nephrol       Date:  2017-07-20       Impact factor: 8.237

7.  Percutaneous transluminal angioplasty of malfunctioning Brescia-Cimino arteriovenous fistula: analysis of factors adversely affecting long-term patency.

Authors:  Koji Sugimoto; Takanori Higashino; Yoichiro Kuwata; Kazufumi Imanaka; Shozo Hirota; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2002-11-29       Impact factor: 5.315

8.  Metallic stent placement in hemodialysis graft patients after insufficient balloon dilation.

Authors:  Huei-Lung Liang; Huay-Ben Pan; Yih-Huie Lin; Chiung-Yu Chen; Hsiao-Min Chung; Tung-Ho Wu; Kang-Ju Chou; Pin-Hong Lai; Chien-Fang Yang
Journal:  Korean J Radiol       Date:  2006 Apr-Jun       Impact factor: 3.500

Review 9.  Novel therapies for hemodialysis vascular access dysfunction: myth or reality?

Authors:  Christi M Terry; Laura M Dember
Journal:  Clin J Am Soc Nephrol       Date:  2013-11-14       Impact factor: 8.237

Review 10.  Pre-emptive correction for haemodialysis arteriovenous access stenosis.

Authors:  Pietro Ravani; Robert R Quinn; Matthew J Oliver; Divya J Karsanji; Matthew T James; Jennifer M MacRae; Suetonia C Palmer; Giovanni F M Strippoli
Journal:  Cochrane Database Syst Rev       Date:  2016-01-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.