Literature DB >> 9394902

Comparison of loads on internal spinal fixation devices measured in vitro and in vivo.

A Rohlmann1, G Bergmann, F Graichen, U Weber.   

Abstract

The loads on internal spinal fixation devices were measured using modified, telemeterized AO-Dick internal fixators. The implants allow measurement of the three force components and the three moments acting on the implant. The modified fixators were mounted on cadaver spines, and the implant loads were measured in the intact and postcorpectomy spines for different loading modes, including axial compression force, flexion, extension, lateral bending, and torsion. The in vitro experiment did not consider muscle forces. Modified fixators were also implanted in three patients, and the implant loads were determined before and after anterior interbody fusion with autologous iliac-crest bone grafts. The results for different in vitro loading modes were compared with those in vivo in order to demonstrate the extent to which the in vitro loads represent the real situation in patients. In several cases, the implant loads in the in vitro experiment differed strongly from those measured in patients. For flexion and lateral bending, a tensile axial force occasionally was measured in the in vitro experiment, while in the patients the axial force was always compressive. Extension was predominantly associated with extension bending moments in the in vitro study but with flexion bending moments in the patients. When muscle forces are not considered in the in vitro experiment, the loads on the fixators may differ significantly from the situation found in patients.

Entities:  

Mesh:

Year:  1997        PMID: 9394902     DOI: 10.1016/s1350-4533(97)00018-0

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  11 in total

1.  [Stress levels in bones and bone cement in the thoracolumbar spine afer kyphoplasty. Finite element study].

Authors:  L M Villarraga Ph D; P A Cripton; A J Bellezza; U Berlemann; S M Kurtz; A A Edidin
Journal:  Orthopade       Date:  2004-01       Impact factor: 1.087

2.  Effect of the intra-abdominal pressure and the center of segmental body mass on the lumbar spine mechanics - a computational parametric study.

Authors:  W M Park; S Wang; Y H Kim; K B Wood; J A Sim; G Li
Journal:  J Biomech Eng       Date:  2012-01       Impact factor: 2.097

3.  Biomechanical evaluation of the Total Facet Arthroplasty System® (TFAS®): loading as compared to a rigid posterior instrumentation system.

Authors:  Simon G Sjovold; Qingan Zhu; Anton Bowden; Chad R Larson; Peter M de Bakker; Marta L Villarraga; Jorge A Ochoa; David M Rosler; Peter A Cripton
Journal:  Eur Spine J       Date:  2012-03-10       Impact factor: 3.134

4.  Effect of augmentation techniques on the failure of pedicle screws under cranio-caudal cyclic loading.

Authors:  Richard Bostelmann; Alexander Keiler; Hans Jakob Steiger; Armin Scholz; Jan Frederick Cornelius; Werner Schmoelz
Journal:  Eur Spine J       Date:  2015-03-27       Impact factor: 3.134

5.  Preclinical evaluation of posterior spine stabilization devices: can the current standards represent basic everyday life activities?

Authors:  Luigi La Barbera; Fabio Galbusera; Hans-Joachim Wilke; Tomaso Villa
Journal:  Eur Spine J       Date:  2016-05-28       Impact factor: 3.134

6.  Preclinical evaluation of posterior spine stabilization devices: can we compare in vitro and in vivo loads on the instrumentation?

Authors:  Luigi La Barbera; Fabio Galbusera; Hans-Joachim Wilke; Tomaso Villa
Journal:  Eur Spine J       Date:  2016-09-16       Impact factor: 3.134

Review 7.  'SMART' implantable devices for spinal implants: a systematic review on current and future trends.

Authors:  Sihyong J Kim; Tian Wang; Matthew H Pelletier; William R Walsh
Journal:  J Spine Surg       Date:  2022-03

Review 8.  Implantable sensor technology: measuring bone and joint biomechanics of daily life in vivo.

Authors:  Darryl D D'Lima; Benjamin J Fregly; Clifford W Colwell
Journal:  Arthritis Res Ther       Date:  2013-01-31       Impact factor: 5.156

9.  Smart implants in orthopedic surgery, improving patient outcomes: a review.

Authors:  Eric H Ledet; Benjamin Liddle; Katerina Kradinova; Sara Harper
Journal:  Innov Entrep Health       Date:  2018-08-29

Review 10.  Comparison of In Vivo Intradiscal Pressure between Sitting and Standing in Human Lumbar Spine: A Systematic Review and Meta-Analysis.

Authors:  Jia-Qi Li; Wai-Hang Kwong; Yuk-Lam Chan; Masato Kawabata
Journal:  Life (Basel)       Date:  2022-03-20
View more