We have developed a convolution/superposition method to calculate dose distributions in photon treatment fields with beam modifiers such as physical wedges. The dose component due to wedge generated radiation was accounted for by using an extended phantom model, which integrated a wedge, an air gap, and a patient phantom as the calculation phantom. The inhomogeneities in the extended phantom and the effect of beam hardening by the wedge were both corrected for in the convolution dose calculation. The calculated dose was verified by Monte Carlo simulation of the same extended phantom. A new dual photon source model was also used in the convolution method to account for both primary photons from the target and extra-focal photons from the primary collimator and flattening filter. Thus, realistic photon energy fluence distributions in the extended phantom were used for the dose calculation. The calculated dose distributions and the wedge factors agreed with the measured data within 2% for a variety of treatment fields including asymmetric fields. Our results showed that the wedge-generated radiation could contribute a significant fraction of the total dose in patients. This dose component depends on a specific field configuration, thus wedge factor changes with photon energy, wedge angle, field size, depth, and patient phantom SSD. The variation of the wedge factor can be predicted accurately by our convolution approach with the extended phantom model, which allows for more accurate dose or monitor unit computation for photon fields with beam modifiers.

Entities:  

Mesh:

Year:  1997        PMID: 9394279     DOI: 10.1118/1.597959

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

Review 1.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

2.  Verification of the accuracy of a photon dose-calculation algorithm.

Authors:  Kent A Gifford; David S Followill; H Helen Liu; George Starkschall
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

3.  Determination of field size-dependent wedge factors from a few selected measurements.

Authors:  Richard A Popple; Ivan A Brezovich; Jun Duan; Sui Shen; Prem N Pareek; Sung-Joon Ye
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.