Abstract

PURPOSE: To evaluate two key processing steps for detection of colon polyps with spiral computed tomographic (CT) colography with perspective volume rendering (PVR): image reconstruction and opacity assignment of the attenuation data.
MATERIALS AND METHODS: Spiral CT was performed in 10 patients with known polyps confirmed at colonoscopy, and detailed quantitative analyses were performed of data obtained in four. First, anatomic fidelity of three-dimensional (3D) images generated from two-dimensional (2D) source images with equal voxel dimensions (87%-90% overlap) was compared with 3D images generated from 2D source images with unequal voxel dimensions (0%-80% overlap). Next, the relative dimensions of colorectal polyps to adjacent structures were evaluated for various opacity threshold settings. Then, step and sigmoidal opacity functions were compared with respect to image smoothness and edge sharpness.
RESULTS: PVR images generated after interpolation of image data reconstructed with at least 60% overlap were equivalent in image quality to PVR images generated from source images with equal voxel dimensions. Relative polyp-to-haustral fold dimensions demonstrated substantial distortions with opacity thresholds below -700 HU. The 3D PVR images generated with the sigmoidal opacity function were significantly smoother than those generated with the step opacity function (paired t test, P < .02), with small differences noted in edge sharpness.
CONCLUSION: Use of highly overlapping source images (87%-90%) was not necessary to generate 3D PVR images of colorectal polyps. Image artifacts were suppressed with use of an appropriate opacity threshold and a sigmoidal opacity function without substantial loss in edge sharpness.

Entities:  

Mesh:

Year:  1997        PMID: 9393524     DOI: 10.1148/radiology.205.3.9393524

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  3 in total

1.  Clinical value of CT three-dimensional imaging in diagnosing gastrointestinal tract diseases.

Authors:  Shao-Yin Duan; Dan-Tong Zhang; Qing-Chi Lin; Yan-Huan Wu
Journal:  World J Gastroenterol       Date:  2006-05-14       Impact factor: 5.742

Review 2.  Virtual colonoscopy: a novel imaging modality for colorectal cancer.

Authors:  D T Rubin; A H Dachman
Journal:  Curr Oncol Rep       Date:  2001-03       Impact factor: 5.075

3.  Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose.

Authors:  Valeria A Fisichella; Magnus Båth; Ase Allansdotter Johnsson; Fredrik Jäderling; Tommy Bergsten; Ulf Persson; Kristin Mellingen; Mikael Hellström
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.