A prospective, randomized study addressing the need for physical simulation following virtual simulation.

R K Valicenti1, F M Waterman, B W Corn, W J Curran.   

Abstract

PURPOSE: To accurately implement a treatment plan obtained by virtual or CT simulation, conventional or physical simulation is still widely used. To evaluate the need for physical simulation, we prospectively randomized patients to undergo physical simulation or no additional simulation after virtual simulation. METHODS AND MATERIALS: From July 1995 to September 1996, 75 patients underwent conformal four-field radiation therapy planning for prostate cancer with a commercial grade CT simulator. The patients were randomized to undergo either port filming immediately following physical simulation or port filming alone. The precision of implementing the devised plan was evaluated by comparing simulator radiographs and/or port films against the digitally reconstructed radiographs (DRRs) for x, y, and z displacements of the isocenter. Changes in beam aperture were also prospectively evaluated.
RESULTS: Thirty-seven patients were randomized to undergo physical simulation and first day port filming, and 38 had first day treatment verification films only without a physical simulation. Seventy-eight simulator radiographs and 195 first day treatment port films were reviewed. There was no statistically significant reduction in treatment setup error (>5 mm) if patients underwent physical simulation following virtual simulation. No patient required a resimulation, and there was no significant difference in changes of beam aperture.
CONCLUSIONS: Following virtual simulation, physical simulation may not be necessary to accurately implement the conformal four-field technique. Because port filming appears to be sufficient to assure precise and reliable execution of a devised treatment plan, physical simulation may be eliminated from the process of CT based planning when virtual simulation is available.

Entities:  

Mesh:

Year:  1997        PMID: 9392555     DOI: 10.1016/s0360-3016(97)00556-7

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  1 in total

1.  Performance evaluation of a dedicated computed tomography scanner used for virtual simulation using in-house fabricated CT phantoms.

Authors:  D S Sharma; S D Sharma; K K Sanu; S Saju; D D Deshpande; S Kannan
Journal:  J Med Phys       Date:  2006-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.