Literature DB >> 9387003

Perspectives on development of IEEE 1073: the Medical Information Bus (MIB) standard.

R J Kennelly1, R M Gardner.   

Abstract

Automated data capture from bedside patient medical devices is now possible using a new Institute of Electrical and Electronic Engineering (IEEE) and American National Standards Institute (ANSI) Medical Information Bus (MIB) data communications standard (IEEE 1073). The first two standard documents, IEEE 1073.3.1 (Transportation Profile) and IEEE 1073.4.1 (Physical Layer), define the hardware protocol for bedside device communications. With the above noted IEEE MIB standards in place, hospitals can now start designing customized applications for acquiring data from bedside devices such as bedside monitors, i.v. pumps, ventilators, etc. for multiple purposes. The hardware 'plug and play' features of the MIB will enable nurses and physicians to establish communications with these devices simply and conveniently by plugging them into a bedside data connector. No other action will be necessary to establish identification of the device or communications with the device. Presently to connect bedside devices, technical help from hardware and software experts are required to establish such communications links. As a result of standardization of communications, it will be easy to establish a highly mobile network of bedside devices and more promptly and efficiently collect patient related data. Collection of data automatically should lead to the design of new medical computing applications that will tie in directly with the emerging mission and operations of hospitals. The MIB will permit acquisition of patient data more efficiently with greater accuracy, more completeness and more promptly. The above noted features are all essential to the development of computerized treatment protocols and should lead to improved quality of patient care. This manuscript provides the rational and historical overview of the development of the MIB standard.

Entities:  

Mesh:

Year:  1997        PMID: 9387003     DOI: 10.1007/bf03356588

Source DB:  PubMed          Journal:  Int J Clin Monit Comput        ISSN: 0167-9945


  3 in total

1.  Applying the ISO/IEEE 11073 standards to wearable home health monitoring systems.

Authors:  Jianchu Yao; Steve Warren
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

2.  Assessing data quality in manual entry of ventilator settings.

Authors:  David K Vawdrey; Reed M Gardner; R Scott Evans; James F Orme; Terry P Clemmer; Loren Greenway; Frank A Drews
Journal:  J Am Med Inform Assoc       Date:  2007-02-28       Impact factor: 4.497

3.  So What? A Tribute to Dr. Reed M. Gardner, PhD, FACMI.

Authors:  R Scott Evans
Journal:  Appl Clin Inform       Date:  2021-02-26       Impact factor: 2.342

  3 in total