Literature DB >> 938111

Isotope angiography: technique, validation and value in the assessment of arterial reconstruction.

C M Moss, A Z Rudavsky, F J Veith.   

Abstract

Isotope angiography performed by intravenous injection of technetium 99m pertechnetate has been demonstrated to be of value in the diagnosis and management of a variety of disorders of the large arteries. An improved technique of isotope angiography is described and the technique validated (53 cases) in normal and diseased arteries by correlating it with conventional contrast arteriography and/or operative findings. Peripheral arteries as far distal as the wrist or mid-calf have been accurately visualized and quantitation of isotope arrival times and total isotope activity in different parts of the arterial tree has provided a means of evaluating the hemodynamic significance of stenosing lesions. Thirty-nine arterial reconstructions were studied by this technique. Seven of 27 (26%) clinically patent arterial reconstructions were found to be harboring significant and potentially dangerous imperfections which were clinically unsuspected. Nine of 12 (75%) arterial reconstructions thought clinically to be occluded were demonstrated to be patent, obviating the need for invasive contrast arteriography. Isotope angiography may be used with no risk for the immediate postoperative and long-term evaluation of arterial reconstructions. Only those patients with abnormalities identified on isotope angiography need have conventional contrast arteriography for further delineation of the abnormality so that it may be repaired before it causes failure of the reconstruction.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 938111      PMCID: PMC1344317          DOI: 10.1097/00000658-197607000-00019

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


  14 in total

1.  EVALUATION OF A SIMPLE TECHNIQUE FOR ABRUPT INTRAVENOUS INJECTION OF RADIOISOTOPE.

Authors:  W H OLDENDORF; M KITANO; S SHIMIZU
Journal:  J Nucl Med       Date:  1965-03       Impact factor: 10.057

2.  Radionuclide aortography in detection of arterial aneurysms.

Authors:  J J Bergan; J S Yao; R E Henkin; J L Quinn
Journal:  Arch Surg       Date:  1974-07

3.  The use of the ultrasonic flow meter in peripheral vascular disease.

Authors:  J Nayman
Journal:  Aust N Z J Surg       Date:  1974-05

4.  Biologic fate of autogenous vein implants as arterial substitutes: clinical, angiographic and histopathologic observations in femoro-popliteal operations for atherosclerosis.

Authors:  D E Szilagyi; J P Elliott; J H Hageman; R F Smith; C A Dall'olmo
Journal:  Ann Surg       Date:  1973-09       Impact factor: 12.969

5.  Application of ultrasound to arterial and venous diagnosis.

Authors:  J S Yao; J J Bergan
Journal:  Surg Clin North Am       Date:  1974-02       Impact factor: 2.741

6.  Radionuclide angiography in the diagnosis of aortocaval fistula. Report of two cases.

Authors:  J C Birnholz
Journal:  J Thorac Cardiovasc Surg       Date:  1973-02       Impact factor: 5.209

7.  Value of the routine use of the cerebral dynamic radioisotope study.

Authors:  R J Cowan; C D Maynard; I Meschan; R Janeway; K Shigeno
Journal:  Radiology       Date:  1973-04       Impact factor: 11.105

8.  Radionuclide demonstration of traumatic arterial injury.

Authors:  A B Diamond; C H Meng; A C Wolanske; L M Freeman
Journal:  Radiology       Date:  1973-12       Impact factor: 11.105

9.  Visualization of arterial and arterial graft patency by intravenous radionuclide angiography.

Authors:  H Meindok
Journal:  Can Med Assoc J       Date:  1972-06-10       Impact factor: 8.262

10.  Detection of carotid artery obstruction by intravenous radionuclide angiography.

Authors:  R J Griep; G Wise; R Marty
Journal:  Radiology       Date:  1970-11       Impact factor: 11.105

View more
  1 in total

1.  The value of isotope angiography in the diagnosis and management of vascular disease.

Authors:  J M Nee; T V Keaveney; G Duffy
Journal:  Ir J Med Sci       Date:  1986-05       Impact factor: 1.568

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.