Literature DB >> 9379057

Comparison of tethering and rolling of eosinophils and neutrophils through selectins and P-selectin glycoprotein ligand-1.

K D Patel1, R P McEver.   

Abstract

We compared the abilities of selectins and the selectin ligand, P-selectin glycoprotein ligand-1 (PSGL-1), to support tethering and rolling of eosinophils and neutrophils under physiologic flow conditions. Eosinophils and neutrophils accumulated on P-selectin at similar site densities and rolled at similar velocities, but fewer eosinophils than neutrophils accumulated at any P-selectin density. Compared with neutrophils, few eosinophils accumulated on E-selectin except at high densities, and those cells that did accumulate rolled faster than neutrophils. Examination of the mechanisms for accumulation revealed that eosinophils and neutrophils formed similar numbers of primary tethers to P-selectin, whereas eosinophils formed fewer primary tethers to E-selectin than did neutrophils. Compared with neutrophils, adherent eosinophils also supported fewer leukocyte-leukocyte interactions, resulting in diminished secondary tethers to either P- or E-selectin. Studies with mAbs to L-selectin and PSGL-1 demonstrated that neither cell type used L-selectin to form primary tethers to P- or E-selectin. Both eosinophils and neutrophils used the NH2 terminus of PSGL-1 to form primary tethers to P-selectin, but not to E-selectin. Both cell types used L-selectin and PSGL-1 to promote leukocyte-leukocyte interactions and secondary tethers to P- or E-selectin. However, eosinophils developed significantly fewer secondary interactions, probably because they express less L-selectin than do neutrophils.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9379057

Source DB:  PubMed          Journal:  J Immunol        ISSN: 0022-1767            Impact factor:   5.422


  17 in total

1.  Correlating the kinetics of cytokine-induced E-selectin adhesion and expression on endothelial cells.

Authors:  J D Levin; H P Ting-Beall; R M Hochmuth
Journal:  Biophys J       Date:  2001-02       Impact factor: 4.033

2.  Particle diameter influences adhesion under flow.

Authors:  V R Shinde Patil; C J Campbell; Y H Yun; S M Slack; D J Goetz
Journal:  Biophys J       Date:  2001-04       Impact factor: 4.033

3.  STAT-6-mediated control of P-selectin by substance P and interleukin-4 in human dermal endothelial cells.

Authors:  Yasuhiro Miyazaki; Takahiro Satoh; Kiyoshi Nishioka; Hiroo Yokozeki
Journal:  Am J Pathol       Date:  2006-08       Impact factor: 4.307

4.  VCAM-1 contributes to rapid eosinophil accumulation induced by the chemoattractants PAF and LTB4: evidence for basal expression of functional VCAM-1 in rat skin.

Authors:  D Davies; K Larbi; A Allen; M Sanz; V B Weg; D O Haskard; R R Lobb; S Nourshargh
Journal:  Immunology       Date:  1999-05       Impact factor: 7.397

5.  Sialyl Lewis(x)-mediated, PSGL-1-independent rolling adhesion on P-selectin.

Authors:  S D Rodgers; R T Camphausen; D A Hammer
Journal:  Biophys J       Date:  2000-08       Impact factor: 4.033

6.  Intercellular cell adhesion molecule-1, vascular cell adhesion molecule-1, and regulated on activation normal T cell expressed and secreted are expressed by human breast carcinoma cells and support eosinophil adhesion and activation.

Authors:  S Ali; J Kaur; K D Patel
Journal:  Am J Pathol       Date:  2000-07       Impact factor: 4.307

7.  Synthesis of {alpha}(1,3) fucosyltransferases IV- and VII-dependent eosinophil selectin ligand and recruitment to the skin.

Authors:  Takahiro Satoh; Yasumasa Kanai; Ming-Hua Wu; Hiroo Yokozeki; Reiji Kannagi; John B Lowe; Kiyoshi Nishioka
Journal:  Am J Pathol       Date:  2005-09       Impact factor: 4.307

8.  P-selectin glycoprotein ligand-1-deficient mice have impaired leukocyte tethering to E-selectin under flow.

Authors:  Lijun Xia; Markus Sperandio; Tadayuki Yago; J Michael McDaniel; Richard D Cummings; Sonia Pearson-White; Klaus Ley; Rodger P McEver
Journal:  J Clin Invest       Date:  2002-04       Impact factor: 14.808

9.  P-selectin glycoprotein ligand-1 deficiency augments G-CSF induced myeloid cell mobilization.

Authors:  Kornél Miszti-Blasius; Szabolcs Felszeghy; Csongor Kiss; Ilona Benkő; Krisztina Géresi; Attila Megyeri; Zsuzsanna Hevessy; János Kappelmayer
Journal:  Naunyn Schmiedebergs Arch Pharmacol       Date:  2013-10-05       Impact factor: 3.000

10.  Estimating the efficiency of cell capture and arrest in flow chambers: study of neutrophil binding via E-selectin and ICAM-1.

Authors:  Yi Zhang; Sriram Neelamegham
Journal:  Biophys J       Date:  2002-10       Impact factor: 4.033

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.