Literature DB >> 9375989

Invasive haemodynamic monitoring: concepts and practical approaches.

J Jalonen1.   

Abstract

The goal of haemodynamic care is to ensure adequate organ blood flow and oxygen supply. Clinical signs of organ perfusion have limited value in estimation of tissue perfusion, but invasive haemodynamic monitoring is needed to gain information of the underlying pathological condition and to guide oxygen delivery and haemodynamic therapy. Many of the available haemodynamic measurements involve pulmonary artery (PA) catheterization. Pressure measurements from PA catheters require meticulous attention to the dynamic properties of the transducer-pressure line system and appreciation of pressure variation owing to respiration. New techniques of continuous measurement of mixed venous oxygen saturation and cardiac output provide valuable trend data, allowing immediate diagnosis and treatment of pathological changes. Fast-response thermistor PA catheters are useful tools for estimating right ventricular function. Although clinicians generally regard PA-catheter data as a valuable therapy guide, few studies showing the beneficial influence on overall outcome have been carried out, and some studies have reported suboptimal understanding and utilization of these data. Transoesophageal echocardiography (TEE) is also a valuable monitor of left ventricular systolic and diastolic function and myocardial ischaemia in anaesthetized patients and in intensive care settings, but it requires a trained operator and is time-consuming. Continuously displayed TEE data, obtainable with automatic border detection, will make TEE even more useful in the near future. More effective monitors of perfusion and oxygenation of individual organs are needed. Less invasive techniques are also constantly sought. Combining data from several noninvasive monitors, including measurements of pulse oximetric O2 saturation, transthoracic impedance cardiac output and transcutaneous oxygen tension, has been reported to reflect closely changes obtained with more invasive monitoring.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9375989     DOI: 10.3109/07853899708999354

Source DB:  PubMed          Journal:  Ann Med        ISSN: 0785-3890            Impact factor:   4.709


  3 in total

1.  Lissajous figures: an engineering tool for root cause analysis of individual cases--a preliminary concept.

Authors:  Kenneth Palmer; Tim Ridgway; Omar Al-Rawi; Ian Johnson; Michael Poullis
Journal:  J Extra Corpor Technol       Date:  2011-09

2.  Uncertainty Quantification in a Patient-Specific One-Dimensional Arterial Network Model: EnKF-Based Inflow Estimator.

Authors:  Andrea Arnold; Christina Battista; Daniel Bia; Yanina Zócalo German; Ricardo L Armentano; Hien Tran; Mette S Olufsen
Journal:  J Verif Valid Uncertain Quantif       Date:  2017-02-22

3.  Lack of difference between continuous versus intermittent heparin infusion on maintenance of intra-arterial catheter in postoperative pediatric surgery: a randomized controlled study.

Authors:  Maria Carolina Witkowski; Maria Antonieta P de Moraes; Cora Maria F Firpo
Journal:  Rev Paul Pediatr       Date:  2013-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.