Literature DB >> 9373924

Carbon monoxide poisonings from small, gasoline-powered, internal combustion engines: just what is a "well-ventilated area"?

G S Earnest1, R L Mickelsen, J B McCammon, D M O'Brien.   

Abstract

This study modeled the time required for a gasoline-powered, 5 horsepower (hp), 4-cycle engine to generate carbon monoxide (CO) concentrations exceeding the National Institute for Occupational Safety and Health 200-ppm ceiling and 1200-ppm immediately dangerous to life and health concentration for various room sizes and ventilation rates. The model permitted the ambiguous term "well-ventilated area" to be defined. The model was compared with field data collected at a site where two workers were poisoned while operating a 5-hp concrete saw in a bathroom having open doors and an operating ventilation system. There is agreement between both the modeled and field-generated data, indicating that hazardous CO concentrations can develop within minutes. Comparison of field and modeling data showed the measured CO generation rate at approximately one-half of the value used in the model, which may be partially because the engine used in the field was not under load during data collection. The generation rate and room size from the actual poisoning was then used in the model. The model determined that ventilation rates of nearly 5000 ft3/min (120 air changes per hour) would be required to prevent the CO concentration from exceeding the 200-ppm ceiling for short periods. Results suggest that small gasoline-powered engines should not be operated inside of buildings or in semienclosed spaces and that manufacturers of such tools should improve their warnings and develop engineering control options for better user protection.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9373924     DOI: 10.1080/15428119791012289

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  1 in total

1.  Prevention against carbon monoxide poisoning emanating from burning coal briquettes - Generation rate of carbon monoxide and ventilation requirement.

Authors:  Jun Ojima
Journal:  Ind Health       Date:  2021-10-27       Impact factor: 2.707

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.