Literature DB >> 9370843

Mechanical obstruction in the anaesthesia delivery-system mimicking severe bronchospasm.

D Aarhus1, E Søreide, H Holst-Larsen.   

Abstract

We present a case where mechanical obstruction in the anaesthesia delivery system caused by plastic wrapping from a filter was misinterpreted as severe bronchospasm. The patient suffered severe hypoxia before the problem was solved by using a free-standing self-expanding ventilation bag. This near-fatal incident emphasises the importance of thorough equipment checking routines, rapid troubleshooting and how equipment failure may be misinterpreted as a medical complication. It also shows how transparent container material can become a medical hazard.

Entities:  

Mesh:

Year:  1997        PMID: 9370843     DOI: 10.1111/j.1365-2044.1997.217-az0351.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  2 in total

1.  Acute obstruction of an endotracheal tube: a case report.

Authors:  Changjoo Park; Hyunjeong Kim; Kwangwon Yum
Journal:  Anesth Prog       Date:  2004

2.  Unidirectional valve malfunction by the breakage or malposition of disc - two cases report -.

Authors:  Chol Lee; Kyu Chang Lee; Hye Young Kim; Mi Na Kim; Eun Kyung Choi; Ji-Sub Kim; Won Sang Lee; Myeong Jong Lee; Hyung Tae Kim
Journal:  Korean J Anesthesiol       Date:  2013-10-24