Literature DB >> 9370471

Quantitative spatially resolved measurements of mass transfer through laryngeal cartilage.

J V Macpherson1, D O'Hare, P R Unwin, C P Winlove.   

Abstract

The scanning electrochemical microscope (SECM) is a scanned probe microscope that uses the response of a mobile ultramicroelectrode (UME) tip to determine the reactivity, topography, and mass transport characteristics of interfaces with high spatial resolution. SECM strategies for measuring the rates of solute diffusion and convection through samples of cartilage, using amperometric UMEs, are outlined. The methods are used to determine the diffusion coefficients of oxygen and ruthenium(III) hexamine [Ru(NH3)6(3+)] in laryngeal cartilage. The diffusion coefficient of oxygen in cartilage is found to be approximately 50% of that in aqueous electrolyte solution, assuming a partition coefficient of unity for oxygen between cartilage and aqueous solution. In contrast, diffusion of Ru(NH3)6(3+) within the cartilage sample cannot be detected on the SECM timescale, suggesting a diffusion coefficient at least two orders of magnitude lower than that in solution, given a measured partition coefficient for Ru(NH3)6(3+) between cartilage and aqueous solution, Kp = [Ru(NH3)6(3+)]cartilage/[RU(NH3)6(3+)]solution = 3.4 +/- 0.1. Rates of Ru(NH3)6(3+) osmotically driven convective transport across cartilage samples are imaged at high spatial resolution by monitoring the current response of a scanning UME, with an osmotic pressure of approximately 0.75 atm across the slice. A model is outlined that enables the current response to be related to the local flux. By determining the topography of the sample from the current response with no applied osmotic pressure, local transport rates can be correlated with topographical features of the sample surface, at much higher spatial resolution than has previously been achieved.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9370471      PMCID: PMC1181179          DOI: 10.1016/S0006-3495(97)78306-1

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  20 in total

Review 1.  Biophysical chemistry of cartilaginous tissues with special reference to solute and fluid transport.

Authors:  A Maroudas
Journal:  Biorheology       Date:  1975-06       Impact factor: 1.875

2.  Chemical imaging of surfaces with the scanning electrochemical microscope.

Authors:  A J Bard; F R Fan; D T Pierce; P R Unwin; D O Wipf; F Zhou
Journal:  Science       Date:  1991-10-04       Impact factor: 47.728

3.  Transient solute diffusion in articular cartilage.

Authors:  P A Torzilli; T C Adams; R J Mis
Journal:  J Biomech       Date:  1987       Impact factor: 2.712

4.  Application of scanning electrochemical microscopy to biological samples.

Authors:  C Lee; J Kwak; A J Bard
Journal:  Proc Natl Acad Sci U S A       Date:  1990-03       Impact factor: 11.205

5.  Surface and subsurface morphology of bovine humeral articular cartilage as assessed by atomic force and transmission electron microscopy.

Authors:  J S Jurvelin; D J Müller; M Wong; D Studer; A Engel; E B Hunziker
Journal:  J Struct Biol       Date:  1996 Jul-Aug       Impact factor: 2.867

6.  Direct imaging of molecular transport through skin.

Authors:  E R Scott; J B Phipps; H S White
Journal:  J Invest Dermatol       Date:  1995-01       Impact factor: 8.551

7.  Iontophoretic transport through porous membranes using scanning electrochemical microscopy: application to in vitro studies of ion fluxes through skin.

Authors:  E R Scott; H S White; J B Phipps
Journal:  Anal Chem       Date:  1993-06-01       Impact factor: 6.986

8.  Transport of ionic species in skin: contribution of pores to the overall skin conductance.

Authors:  E R Scott; A I Laplaza; H S White; J B Phipps
Journal:  Pharm Res       Date:  1993-12       Impact factor: 4.200

9.  Diffusion of small solutes in cartilage as measured by nuclear magnetic resonance (NMR) spectroscopy and imaging.

Authors:  D Burstein; M L Gray; A L Hartman; R Gipe; B D Foy
Journal:  J Orthop Res       Date:  1993-07       Impact factor: 3.494

10.  Visualisation of mass transport of small organic molecules and metal ions through articular cartilage by magnetic resonance imaging.

Authors:  A E Fischer; T A Carpenter; J A Tyler; L D Hall
Journal:  Magn Reson Imaging       Date:  1995       Impact factor: 2.546

View more
  4 in total

1.  Design and characterization of a microfabricated hydrogen clearance blood flow sensor.

Authors:  Lindsay R Walton; Martin A Edwards; Gregory S McCarty; R Mark Wightman
Journal:  J Neurosci Methods       Date:  2016-04-19       Impact factor: 2.390

2.  Optimizing the medium perfusion rate in bone tissue engineering bioreactors.

Authors:  Warren L Grayson; Darja Marolt; Sarindr Bhumiratana; Mirjam Fröhlich; X Edward Guo; Gordana Vunjak-Novakovic
Journal:  Biotechnol Bioeng       Date:  2010-12-22       Impact factor: 4.530

3.  Scanning electrochemical microscopy as a local probe of oxygen permeability in cartilage.

Authors:  M Gonsalves; A L Barker; J V Macpherson; P R Unwin; D O'Hare; C P Winlove
Journal:  Biophys J       Date:  2000-03       Impact factor: 4.033

4.  Strain-dependent oxygen diffusivity in bovine annulus fibrosus.

Authors:  T-Y Yuan; A R Jackson; C-Y Huang; W Y Gu
Journal:  J Biomech Eng       Date:  2009-07       Impact factor: 2.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.