Literature DB >> 9368386

Automated microanalysis using magnetic beads with commercial capillary electrophoretic instrumentation.

L G Rashkovetsky1, Y V Lyubarskaya, F Foret, D E Hughes, B L Karger.   

Abstract

The potential of a new microanalytical method using magnetic beads (MBs) and commercial capillary electrophoresis (CE) instrumentation for performing enzymatic and inhibition assays, as well as for analysis of biological molecules such as antigens, substrates, etc., has been explored. A small quantity of magnetic beads containing immobilized biomolecules was injected into a neutral hydrophilic-coated fused-silica capillary. The short plug (2-3 mm) of beads was held fixed by a magnet placed in the cartridge of the CE system, without the use of frits. The beads could be replaced after each run, eliminating the need to regenerate the solid support. Two protocols were used for analysis: sequential injection (SI) and SI followed by isotachophoretic (ITP) focusing. Alkaline phosphatase (AP) and HIV-protease were used to demonstrate the SI procedure for enzymatic and inhibition assays. The second protocol, SI/ITP, was employed to quantitate an antigen (mouse mAB) using antibodies (sheep IgG towards mouse AB) immobilized on the beads. The MB-CE method, requiring only femtomole (fmol) quantities of material, can potentially be employed in diagnostic and forensic assays, kinetic studies and searching for inhibitors, ligands, receptors, etc.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9368386     DOI: 10.1016/s0021-9673(97)00629-8

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  A replaceable microreactor for on-line protein digestion in a two-dimensional capillary electrophoresis system with tandem mass spectrometry detection.

Authors:  Yihan Li; Roza Wojcik; Norman J Dovichi
Journal:  J Chromatogr A       Date:  2010-10-27       Impact factor: 4.759

2.  On-chip immuno-agglutination assay based on a dynamic magnetic bead clump and a sheath-less flow cytometry.

Authors:  Shuai Zhang; Zengshuai Ma; Yushu Zhang; Yue Wang; Yinuo Cheng; Wenhui Wang; Xiongying Ye
Journal:  Biomicrofluidics       Date:  2019-07-11       Impact factor: 2.800

3.  Influence of immobilized biomolecules on magnetic bead plug formation and retention in capillary electrophoresis.

Authors:  Rachel L Henken; Rattikan Chantiwas; S Douglass Gilman
Journal:  Electrophoresis       Date:  2012-03-21       Impact factor: 3.535

4.  Improved peak capacity for CE separations of enzyme inhibitors with activity-based detection using magnetic bead microreactors.

Authors:  Xiaoyan Yan; S Douglass Gilman
Journal:  Electrophoresis       Date:  2010-01       Impact factor: 3.535

5.  Automated enzyme-based diagonal capillary electrophoresis: application to phosphopeptide characterization.

Authors:  Roza Wojcik; Michael Vannatta; Norman J Dovichi
Journal:  Anal Chem       Date:  2010-02-15       Impact factor: 6.986

Review 6.  Immunoaffinity capillary electrophoresis as a powerful strategy for the quantification of low-abundance biomarkers, drugs, and metabolites in biological matrices.

Authors:  Norberto A Guzman; Timothy Blanc; Terry M Phillips
Journal:  Electrophoresis       Date:  2008-08       Impact factor: 3.535

7.  Magnetic Particle Plug-Based Assays for Biomarker Analysis.

Authors:  Chayakom Phurimsak; Mark D Tarn; Nicole Pamme
Journal:  Micromachines (Basel)       Date:  2016-04-26       Impact factor: 2.891

  7 in total