Literature DB >> 9364632

Kinetics of repair in the spinal cord of the rat.

W Landuyt1, J Fowler, A Ruifrok, G Stüben, A van der Kogel, E van der Schueren.   

Abstract

PURPOSE: Split dose experiments were carried out with two 2 Gy fractions per day at intervals ranging from 0.5 to 24 h, in order to investigate both the time to complete repair and the detailed kinetics of repair of sublethal damage in the cervical spine of rats.
MATERIALS AND METHODS: Male rats of the WAG/Rij strain were irradiated at 2 Gy/min with 18 MV photons to a length of 18 mm of cervical spinal cord. Four hundred twenty-three rats were irradiated without top-up doses to investigate whether repair was complete by 24 h or whether any slow repair or proliferation occurred up to 50 days after irradiation. Three hundred seventy-nine rats were also irradiated in split dose (2 Gy + delta t + 2 Gy each day) experiments, with intervals of 0.5, 1, 2, 4, 8 and 24 h. The split dose irradiations were followed by a single top-up dose of 15 Gy (producing about half the total damage).
RESULTS: Repair was complete by 24 h as the ED50 values were the same at 1, 11 and 50 day intervals for two large fractions, and for 10 fractions in 10 or 50 days. A mono-exponential component of repair of T1/2 = 0.25 (95% CI 0.16-0.48) h was determined by direct analysis using all the data and T1/2 = 0.37 (0.28-0.53) h for the split 2 Gy doses with top-up only. A bi-exponential analysis did not fit better. The presence of a second component was demonstrated graphically, with T1/2 of about 6.5 h but with a wide confidence interval from near 0 to 13 h. However, the 24 h ED50 was significantly different from all ED50s except the 8 h value. Considering all data together, an upper limit of about 7 h could be placed on any long component, or else repair could not be complete by 24 h. DISCUSSION AND
CONCLUSIONS: Two components of repair (0.7 and 3.8 h) have been reported by Ang et al. (Ang, K.K., Jiang, G.L., Guttenberger, R., Thames, H.D., Stephens, L.C., Smith, C.D. and Feng, Y. Impact of spinal cord repair kinetics on the practice of altered fractionation schedules. Radiother. Oncol. 25: 287-294, 1992) in the spinal cord of Sprague-Dawley rats. Two components have also been reported by others more recently. The present results could, with its graphical interpretation, agree in principle, but with a shorter fast component and a longer slow component. A slow component of 5.5 h was reported by Ruifrok et al. (Ruifrok, A.C.C., Kleiboer, B.J. and van der Kogel, A.J. Fractionation sensitivity of rat cervical spinal cord during radiation retreatment. Radiother. Oncol. 25: 295-300, 1992) in a related strain of WAG/Rij rats. The possible presence of a slower component than Ang et al.'s 3.8 h might help to explain the four myelopathies observed in the pilot studies for the CHART clinical trial. The presence of the definite fast component (< 0.5 h) could have important consequences when pulsed brachytherapy is used to replace continuous low dose rate irradiation.

Entities:  

Mesh:

Year:  1997        PMID: 9364632     DOI: 10.1016/s0167-8140(97)00139-4

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  5 in total

1.  Radiobiological effects of total body irradiation on the spinal cord.

Authors:  Alexander Nevelsky; Raquel Bar-Deroma; Abraham Kuten
Journal:  Radiat Environ Biophys       Date:  2009-07-30       Impact factor: 1.925

2.  The effect of pentoxifylline on radiobiological parameters in the rat radiation myelopathy.

Authors:  Won Dong Kim; Woo Yoon Park
Journal:  Cancer Res Treat       Date:  2006-12-31       Impact factor: 4.679

3.  Whole-thorax irradiation induces hypoxic respiratory failure, pleural effusions and cardiac remodeling.

Authors:  Meetha Medhora; Feng Gao; Chad Glisch; Jayashree Narayanan; Ashish Sharma; Leanne M Harmann; Michael W Lawlor; Laura A Snyder; Brian L Fish; Julian D Down; John E Moulder; Jennifer L Strande; Elizabeth R Jacobs
Journal:  J Radiat Res       Date:  2014-11-03       Impact factor: 2.724

4.  Compensation for radiotherapy treatment interruptions due to a cyberattack: An isoeffective DVH-based dose compensation decision tool.

Authors:  Katie O'Shea; Linda Coleman; Louise Fahy; Christoph Kleefeld; Mark J Foley; Margaret Moore
Journal:  J Appl Clin Med Phys       Date:  2022-07-20       Impact factor: 2.243

5.  Impact of time-related factors on biologically accurate radiotherapy treatment planning.

Authors:  Yushi Wakisaka; Masashi Yagi; Iori Sumida; Masaaki Takashina; Kazuhiko Ogawa; Masahiko Koizumi
Journal:  Radiat Oncol       Date:  2018-02-23       Impact factor: 3.481

  5 in total