Literature DB >> 9362279

Transesophageal echocardiography in rats using an intravascular ultrasound catheter.

L Lu1, E Ko, G G Schwartz, T M Chou.   

Abstract

In vivo assessment of cardiac structure and function in small animals is an important experimental goal, but currently available techniques have significant limitations. A commercially available intravascular ultrasound (IVUS) system was adapted to perform transesophageal echocardiography (TEE) in rats. Twelve Sprague-Dawley rats (270-370 g) were anesthetized with intraperitoneal pentobarbital sodium. A 4.3-Fr, 30-MHz or an 8-Fr, 20-MHz IVUS catheter was inserted into the esophagus to obtain long-axis views of the aortic arch, short-axis views of the ascending aorta, and long-axis views of the pulmonary artery. A preshaped, 8-Fr, 20-MHz catheter was used to obtain short-axis images of the left ventricle (LV) at the midpapillary muscle level, which were used to measure LV diastolic and systolic dimensions (diameters) and to calculate LV mass and fractional shortening. Measurements by TEE were compared with those obtained by transthoracic echocardiography in 6 of 12 rats. Postmortem, the LV was weighed to determine actual LV mass. The correlation coefficients between TEE- and transthoracic echocardiography-calculated LV mass and actual LV mass were 0.94 and 0.88, respectively, and had a good agreement with actual LV mass. Inter- and intraobserver variability of TEE measurements was <10%. IVUS instrumentation may offer an alternative technique for the accurate, serial assessment of LV dimensions, mass, and systolic function and a means of imaging the great vessels in small laboratory animals.

Entities:  

Mesh:

Year:  1997        PMID: 9362279     DOI: 10.1152/ajpheart.1997.273.4.H2078

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  5 in total

1.  AT2 receptor and apoptosis during AT1 receptor blockade in reperfused myocardial infarction in the rat.

Authors:  Bodh I Jugdutt; Vijayan Menon
Journal:  Mol Cell Biochem       Date:  2004-07       Impact factor: 3.396

Review 2.  Intracardiac echocardiography in congenital heart disease.

Authors:  Piers C A Barker
Journal:  J Cardiovasc Transl Res       Date:  2009-01-23       Impact factor: 4.132

3.  Intravascular ultrasound catheter for transesophageal echocardiography in congenital heart surgery -A case report-.

Authors:  Hye-Jin Kim; Jae-Yun Kim; Seung-Hoon Baek; Hae-Kyu Kim
Journal:  Korean J Anesthesiol       Date:  2010-05-31

4.  Development and testing of gold nanoparticles for drug delivery and treatment of heart failure: a theranostic potential for PPP cardiology.

Authors:  Mykola Ya Spivak; Rostyslav V Bubnov; Ilya M Yemets; Liudmyla M Lazarenko; Natalia O Tymoshok; Zoia R Ulberg
Journal:  EPMA J       Date:  2013-07-29       Impact factor: 6.543

5.  Prospective evaluation of complications associated with transesophageal echocardiography in dogs with congenital heart disease.

Authors:  Caitlin H Stoner; Ashley B Saunders; Johanna C Heseltine; Audrey K Cook; Jonathan A Lidbury
Journal:  J Vet Intern Med       Date:  2022-01-08       Impact factor: 3.333

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.