Literature DB >> 9361918

A newly designed miniplate staple for high tibial osteotomy.

D K Bae1, M S Mun, O S Kwon.   

Abstract

A biomechanical study was made to compare the mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy (HTO). Using twenty fresh porcine tibiae, the fixational strength of the two different types of staples in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with bone densitometry and those with 0.8 to 1.2 gm/cm2 at the proximal tibia were used in the biomechanical test. Testing was performed on a material testing system with aid of a commercial data processor. Using two different loading modes, "pull-out" and "push-out," the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten nonosteotomized specimens were used and the staple was pulled out by subjecting an axial tension on the head of the staple inserted. In the push-out test ten tibiae osteotomized in the usual method of HTO were used and the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the proximal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the distal tibia was fixed. The pull-out strength of Coventry staple and Miniplate staple were found to be 27.88 +/- 5.12 kgf and 182.47 +/- 32.75 kgf, respectively. The push-out strength of Coventry staple and Miniplate staple were 18.40 +/- 4.47 kgf and 119.95 +/- 19.06 kgf, respectively. The result revealed that the Miniplate staple has both a pull-out and push-out strength that is more than six times higher than Coventry staple. Based on the data, it is believed that the Miniplate staple provides better postoperative fixation in HTO. The postoperative application of long leg casting may not be needed after HTO surgery.

Mesh:

Year:  1997        PMID: 9361918

Source DB:  PubMed          Journal:  Bull Hosp Jt Dis        ISSN: 0018-5647


  3 in total

1.  Change in limb length after high tibial osteotomy using computer-assisted surgery: a comparative study of closed- and open-wedge osteotomies.

Authors:  Dae Kyung Bae; Sang Jun Song; Hwan Jin Kim; Jae Wan Seo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-20       Impact factor: 4.342

2.  Computer-assisted navigation decreases the change in the tibial posterior slope angle after closed-wedge high tibial osteotomy.

Authors:  Dae Kyung Bae; Young Wan Ko; Sang Jun Kim; Jong Hun Baek; Sang Jun Song
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-11       Impact factor: 4.342

3.  Comparison of Mechanical Axis and Dynamic Range Assessed with Weight Bearing Radiographs and Navigation System in Closed Wedge High Tibial Osteotomy.

Authors:  Dae Kyung Bae; Jong Whan Lee; Seong Jin Cho; Sang Jun Song
Journal:  Knee Surg Relat Res       Date:  2017-09-01
  3 in total