Validation of multi-frequency bioelectrical impedance analysis in detecting changes in fluid balance of geriatric patients.

M G Olde Rikkert1, P Deurenberg, R W Jansen, M A van't Hof, W H Hoefnagels.   

Abstract

OBJECTIVES: Multi-Frequency Bioelectrical Impedance Analysis (MFBIA) is a quick, simple, and inexpensive method to assess body fluid compartments. This study aimed at determining the validity of MFBIA in detecting clinically relevant changes of fluid balance in geriatric patients.
DESIGN: A prospective, observational study.
SETTING: The 22-bed Geriatric Department of the University Hospital Nijmegen. PARTICIPANTS: Hospitalized patients were eligible if they did not have a pacemaker, were not suffering from terminal illnesses, and did not have psychogeriatric diseases likely to interfere with capacity to consent or comply. During a 16-months period, 218 patients were admitted, of whom 78 patients were eligible and 53 consented to participate. MEASUREMENTS: Each subject's fluid balance was diagnosed twice a week as dehydrated, overhydrated, or euvolemic, based on standardized physical examination, laboratory tests, and weight evaluation. Changes in fluid balance were quantified by measuring total body water (TBW) and extracellular fluid (ECF) applying deuterium- and bromide-dilution techniques. Impedance at 1, 5, 50, and 100 kHz and body weight were measured daily. Sensitivity and Guyatt's responsiveness indexes of MFBIA in detecting dehydration and overhydration were determined.
RESULTS: In total, 1071 MFBIA measurements were performed, during which 14 transitions from dehydration to euvolemia and 13 transitions from overhydration to euvolemia were monitored. Rehydration of dehydrated patients caused an increase in TBW and ECF of 3.4 +/- 1.8 L and 1.9 +/- 1.9 L, respectively, which resulted in significant decreases in impedance of 133 +/- 67 omega at 1 kHz and 93 +/- 61 omega at 100 kHz (P = .001). Treatment of overhydrated patients caused a TBW and ECF loss of 3.8 +/- 4.2 L and 3.1 +/- 3.8 L, respectively, which resulted in significant increases in impedance of 104 +/- 72 omega at 1 kHz and 81 +/- 68 omega at 100 kHz (P < .001). Sensitivity of a single MFBIA in diagnosing dehydration and overhydration was 14% and 17%, respectively. Responsiveness indexes of weighing and MFBIA for dehydration and overhydration were similar at all frequencies and greater than one.
CONCLUSION: The sensitivity of a single impedance measurement in detecting dehydration and overhydration was low. However, responsiveness of serial measurements to intra-individual changes in fluid balance was good. Therefore, this noninvasive technique may be used in clinical practice to improve monitoring fluid balance in geriatric patients, especially when daily weighing is difficult.

Entities:  

Mesh:

Year:  1997        PMID: 9361660     DOI: 10.1111/j.1532-5415.1997.tb02934.x

Source DB:  PubMed          Journal:  J Am Geriatr Soc        ISSN: 0002-8614            Impact factor:   5.562


  11 in total

Review 1.  Clinical aspects of changes in water and sodium homeostasis in the elderly.

Authors:  Christian A Koch; Tibor Fulop
Journal:  Rev Endocr Metab Disord       Date:  2017-03       Impact factor: 6.514

2.  Multi-frequency bioelectrical impedance analysis for assessing fat mass and fat-free mass in stroke or transient ischaemic attack patients.

Authors:  M W Kafri; J F Potter; P K Myint
Journal:  Eur J Clin Nutr       Date:  2014-01-08       Impact factor: 4.016

3.  Bioelectrical impedance analysis is more accurate than clinical examination in determining the volaemic status of elderly patients with fragility fracture and hyponatraemia.

Authors:  K Cumming; G E Hoyle; J D Hutchison; R L Soiza
Journal:  J Nutr Health Aging       Date:  2014       Impact factor: 4.075

Review 4.  Clinical symptoms, signs and tests for identification of impending and current water-loss dehydration in older people.

Authors:  Lee Hooper; Asmaa Abdelhamid; Natalie J Attreed; Wayne W Campbell; Adam M Channell; Philippe Chassagne; Kennith R Culp; Stephen J Fletcher; Matthew B Fortes; Nigel Fuller; Phyllis M Gaspar; Daniel J Gilbert; Adam C Heathcote; Mohannad W Kafri; Fumiko Kajii; Gregor Lindner; Gary W Mack; Janet C Mentes; Paolo Merlani; Rowan A Needham; Marcel G M Olde Rikkert; Andreas Perren; James Powers; Sheila C Ranson; Patrick Ritz; Anne M Rowat; Fredrik Sjöstrand; Alexandra C Smith; Jodi J D Stookey; Nancy A Stotts; David R Thomas; Angela Vivanti; Bonnie J Wakefield; Nana Waldréus; Neil P Walsh; Sean Ward; John F Potter; Paul Hunter
Journal:  Cochrane Database Syst Rev       Date:  2015-04-30

Review 5.  Tear Osmolarity in the Diagnosis of Systemic Dehydration and Dry Eye Disease.

Authors:  Anthony J Bron; Catherine Willshire
Journal:  Diagnostics (Basel)       Date:  2021-02-25

6.  The diagnostic accuracy of multi-frequency bioelectrical impedance analysis in diagnosing dehydration after stroke.

Authors:  Mohannad W Kafri; Phyo Kway Myint; Danielle Doherty; Alexander Hugh Wilson; John F Potter; Lee Hooper
Journal:  Med Sci Monit       Date:  2013-07-10

7.  Which Frail Older People Are Dehydrated? The UK DRIE Study.

Authors:  Lee Hooper; Diane K Bunn; Alice Downing; Florence O Jimoh; Joyce Groves; Carol Free; Vicky Cowap; John F Potter; Paul R Hunter; Lee Shepstone
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2015-11-09       Impact factor: 6.053

Review 8.  The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases.

Authors:  Sami F Khalil; Mas S Mohktar; Fatimah Ibrahim
Journal:  Sensors (Basel)       Date:  2014-06-19       Impact factor: 3.576

Review 9.  Clinical usefulness of bioimpedance analysis for assessing volume status in patients receiving maintenance dialysis.

Authors:  Jung Hwan Park; Young-Il Jo; Jong-Ho Lee
Journal:  Korean J Intern Med       Date:  2018-06-28       Impact factor: 2.884

Review 10.  Dehydration and volume depletion: How to handle the misconceptions.

Authors:  Muhammad Asim; Mohamad M Alkadi; Hania Asim; Adil Ghaffar
Journal:  World J Nephrol       Date:  2019-01-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.