Literature DB >> 936030

Critique of the Allen test for continuity of the palmar arch assessed by doppler ultrasound.

R W Kamienski, R W Barnes.   

Abstract

The arterial circulation of both hands of 128 adults was assessed by the Allen test, a modified Allen test emphasizing proper hand position and by Doppler ultrasound. Full extension of the fingers during the Allen test resulted incomplete capillary refilling of the hand in 73 per cent of the patients. The modified Allen test, avoiding hyperextension of the wrist and fingers, revealed interruption of the palmar arch in only one patient with absence of the left radialy artery. There was complete concordance of findings by Doppler ultrasound and the modified Allen test, emphasizing the importance of maintaining proper hand position to avoid false interpretations of incomplete circulation of the palmar arch.

Entities:  

Mesh:

Year:  1976        PMID: 936030

Source DB:  PubMed          Journal:  Surg Gynecol Obstet        ISSN: 0039-6087


  10 in total

1.  Duplex scanning to assess radial artery suitability for coronary artery bypass grafting.

Authors:  M Hosono; S Suehiro; T Shibata; Y Sasaki; H Kumano; H Kinoshita
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2000-04

2.  Comparative anatomy and histology of the radial artery and the internal thoracic artery. Implication for coronary artery bypass.

Authors:  C Acar; V A Jebara; M Portoghèse; F Fontaliran; P Dervanian; J C Chachques; V Meininger; A Carpentier
Journal:  Surg Radiol Anat       Date:  1991       Impact factor: 1.246

3.  Evolution of complete arterial grafting. For coronary artery disease.

Authors:  B F Buxton; J A Fuller; J Tatoulis
Journal:  Tex Heart Inst J       Date:  1998

4.  Evaluation of a postocclusive reactive circulatory hyperaemia (PORCH) test for the assessment of ulnar collateral circulation.

Authors:  H Vaghadia; M T Schechter; S B Sheps; L C Jenkins
Journal:  Can J Anaesth       Date:  1988-11       Impact factor: 5.063

5.  Incidence of forearm and hand ischaemia related to radial artery cannulation in newborn infants.

Authors:  W W Hack; A Vos; A Okken
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

6.  A study of the superficial palmar arteries using the Doppler Ultrasonic Flowmeter.

Authors:  M Al-Turk; W K Metcalf
Journal:  J Anat       Date:  1984-01       Impact factor: 2.610

Review 7.  Clinical diagnosis by transcutaneous Doppler ultrasound.

Authors:  R K Wyse
Journal:  Postgrad Med J       Date:  1982-04       Impact factor: 2.401

Review 8.  Preoperative vascular access evaluation for haemodialysis patients.

Authors:  Sarah D Kosa; Ahmed A Al-Jaishi; Louise Moist; Charmaine E Lok
Journal:  Cochrane Database Syst Rev       Date:  2015-09-30

9.  Assessment of collateral hand circulation by modified Allen's test in normal Indian subjects.

Authors:  Tanishq Agarwal; Vrinda Agarwal; Pawan Agarwal; Sharad Thakur; Rajesh Bobba; Dhananjaya Sharma
Journal:  J Clin Orthop Trauma       Date:  2020-04-07

Review 10.  Evidence-based Comprehensive Approach to Forearm Arterial Laceration.

Authors:  Janice N Thai; Jose A Pacheco; David S Margolis; Tianyi Swartz; Brandon Z Massey; John A Guisto; Jordan L Smith; Joseph E Sheppard
Journal:  West J Emerg Med       Date:  2015-12-11
  10 in total