Literature DB >> 9357887

Alfentanil blocks reflex pupillary dilation in response to noxious stimulation but does not diminish the light reflex.

M D Larson1, A Kurz, D I Sessler, M Dechert, A R Bjorksten, F Tayefeh.   

Abstract

BACKGROUND: Estimation of the mu-agonist opioid effect in anesthetized and paralyzed patients is often imprecise and can be obscured by concomitant administration of drugs that affect the sympathetic nervous system, such as beta-adrenergic blocking agents. As an alternative to hemodynamic measures of opioid effect, the authors tested the hypothesis that the pupillary light reflex or pupillary reflex dilation correlated with alfentanil concentrations during isoflurane anesthesia.
METHODS: Six volunteers were anesthetized on 4 days with 0.8% isoflurane. Alfentanil was administered intravenously to target total plasma concentrations of 0, 25, 50, and 100 ng/ml. A 5-s tetanic electrical stimulus was applied to the skin. Pupil size and the pupillary light reflex were recorded before and after alfentanil administration, and before and for 8 min after the stimulus.
RESULTS: Alfentanil exponentially impaired reflex pupillary dilation, decreasing the maximum response amplitude from 5 mm at 0 ng/ml, to 2.3 mm at 25 ng/ml, to 1.0 mm at 50 ng/ml, and finally to 0.2 mm at 100 ng/ml. In contrast, only the highest concentration of alfentanil depressed the dilation of the pupil in the first 2 s after the stimulus. Alfentanil administration had no effect on the pupillary light reflex.
CONCLUSIONS: Dilation of the pupil in response to a noxious stimulus is a measure of opioid effect in isoflurane-anesthetized volunteers. In contrast, the pupillary light reflex is unaffected by alfentanil during isoflurane anesthesia. These data suggest that stimulus-induced pupillary dilation may be used to evaluate the analgesic component of a combined volatile and opioid anesthetic.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9357887     DOI: 10.1097/00000542-199710000-00019

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  17 in total

1.  Suppression of pupillary unrest by general anesthesia and propofol sedation.

Authors:  Matthias Behrends; Merlin D Larson; Andrew E Neice; Michael P Bokoch
Journal:  J Clin Monit Comput       Date:  2018-05-21       Impact factor: 2.502

2.  Population pharmacokinetic/pharmacodynamic modelling of the effects of axomadol and its O-demethyl metabolite on pupil diameter and nociception in healthy subjects.

Authors:  Víctor Mangas-Sanjuan; José Martín Pastor; Jens Rengelshausen; Roberta Bursi; Iñaki F Troconiz
Journal:  Br J Clin Pharmacol       Date:  2016-04-14       Impact factor: 4.335

3.  Effect of dexmedetomidine, an alpha2-adrenoceptor agonist, on human pupillary reflexes during general anaesthesia.

Authors:  M D Larson; P O Talke
Journal:  Br J Clin Pharmacol       Date:  2001-01       Impact factor: 4.335

Review 4.  The quantification and monitoring of intraoperative nociception levels in thoracic surgery: a review.

Authors:  Ismael Ghanty; Stefan Schraag
Journal:  J Thorac Dis       Date:  2019-09       Impact factor: 2.895

5.  Pupillary reflex dilation in response to incremental nociceptive stimuli in patients receiving intravenous ketamine.

Authors:  Nada Sabourdin; Thomas Giral; Risa Wolk; Nicolas Louvet; Isabelle Constant
Journal:  J Clin Monit Comput       Date:  2017-10-17       Impact factor: 2.502

6.  Pupillary abnormalities in non-selected critically ill patients: an observational study.

Authors:  Philippe Portran; Martin Cour; Romain Hernu; Sylvie de la Salle; Laurent Argaud
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

7.  Assessment of pain during labor with pupillometry: a prospective observational study.

Authors:  Jean Guglielminotti; France Mentré; Johann Gaillard; Mohamed Ghalayini; Philippe Montravers; Dan Longrois
Journal:  Anesth Analg       Date:  2013-03-11       Impact factor: 5.108

8.  Evaluation of the depth of sedation in an intensive care unit based on the photo motor reflex variations measured by video pupillometry.

Authors:  Ouri Rouche; Aurore Wolak-Thierry; Quentin Destoop; Lucas Milloncourt; Thierry Floch; Pascal Raclot; Damien Jolly; Joël Cousson
Journal:  Ann Intensive Care       Date:  2013-02-22       Impact factor: 6.925

Review 9.  Pupillometry in perioperative medicine: a narrative review.

Authors:  Senthil Packiasabapathy; Valluvan Rangasamy; Senthilkumar Sadhasivam
Journal:  Can J Anaesth       Date:  2021-01-11       Impact factor: 6.713

10.  Pupillary reflex measurement predicts insufficient analgesia before endotracheal suctioning in critically ill patients.

Authors:  Jerome Paulus; Antoine Roquilly; Hélène Beloeil; Julien Théraud; Karim Asehnoune; Corinne Lejus
Journal:  Crit Care       Date:  2013-07-24       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.