Literature DB >> 9356618

Patient dose in radiologically guided interventional vascular procedures: conventional versus digital systems.

R Ruiz-Cruces1, M Pérez-Martínez, A Martín-Palanca, A Flores, J Cristófol, M Martínez-Morillo, A Díez de los Ríos.   

Abstract

PURPOSE: To calculate the difference in the patient radiation dose in radiologically guided interventional vascular procedures between conventional and digital systems and to estimate the effective dose and the energy imparted with the digital system.
MATERIALS AND METHODS: A total of 318 procedures (in 318 patients) in 15 different examination groups were analyzed. The dose-area product was determined by using a transmission chamber fitted to an x-ray-tube light-beam diaphragm; the effective dose was determined by using software.
RESULTS: Urinary and biliary tract procedures showed small differences in the average dose-area product between conventional and digital systems. The dose-area products in the vascular procedures were higher with the digital than with the conventional system. The average effective dose and energy imparted were 0.88 mSv and 129 mJ, respectively, in the subcutaneous placement of a reservoir for analgesic administration and as much as 25.7 mSv and 829 mJ, respectively, in spermatic vein embolization.
CONCLUSION: The dose-area product was higher with the digital system than with the conventional system in 13 of the 15 groups. To reduce the patient dose in vascular interventional radiology procedures, the training of personnel and the frequent use of conventional fluoroscopy and low-dose imaging are required.

Entities:  

Mesh:

Year:  1997        PMID: 9356618     DOI: 10.1148/radiology.205.2.9356618

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  The impact of endoscopic retrograde cholangiopancreatography education on radiation exposure to experienced endoscopist: 'trainee effect'.

Authors:  Erkin Oztas; Erkan Parlak; Fahrettin Kucukay; Mehmet Arhan; Ulku Daglı; Digdem Ozer Etik; Fatih Oguz Onder; Tulay Olcer; Nurgul Sasmaz
Journal:  Dig Dis Sci       Date:  2012-05       Impact factor: 3.199

2.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

3.  Diagnostic reference levels and complexity indices in interventional radiology: a national programme.

Authors:  R Ruiz-Cruces; E Vano; F Carrera-Magariño; F Moreno-Rodriguez; M M Soler-Cantos; M Canis-Lopez; J Hernández-Armas; F J Diaz-Romero; F Rosales-Espizua; J M Fernandez-Soto; R Sanchez-Casanueva; A Martin-Palanca; M Perez-Martinez; A Gil-Agudo; M A Zarca-Diaz; V Parra-Osorio; J J Muñoz Ruiz-Canela; T Moreno-Sanchez; A Lopez-Medina; C Moreno-Saiz; P Galan-Montenegro; J J Gallego-Beuter; M Gonzalez-de-Garay; J C Zapata-Jimenez; J M Pastor-Vega; S Cañete
Journal:  Eur Radiol       Date:  2016-07-06       Impact factor: 5.315

4.  Optimization and audit of radiation dose during percutaneous transluminal coronary angioplasty.

Authors:  Roshan S Livingstone; B S Timothy Peace; Sunil Chandy; Paul V George; Purendra Pati
Journal:  J Med Phys       Date:  2007-10

5.  Transition from image intensifier to flat panel detector in interventional cardiology: Impact of radiation dose.

Authors:  Roshan S Livingstone; David Chase; Anna Varghese; Paul V George; Oommen K George
Journal:  J Med Phys       Date:  2015 Jan-Mar
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.