Literature DB >> 9356068

The use of hemorrhage occluder pins for controlling paravertebral intercostal artery bleeding: case report.

Y Kluger1, B Sagie, D Soffer, N Nasrallha, D Aladgem.   

Abstract

OBJECTIVE: To describe a technique for arresting traumatic bleeding uncontrollable by conventional means. METHODS AND
RESULTS: Major intrathoracic bleeding was stopped in a 17-year-old boy who had been stabbed in his right chest by using a Hemorrhage Occluder Pin (Surgical Instruments Inc., Placetia, Calif).
CONCLUSIONS: The use of occluder pins to stop bleeding from intercostal arteries may be life-saving.

Entities:  

Mesh:

Year:  1997        PMID: 9356068     DOI: 10.1097/00005373-199710000-00020

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  1 in total

1.  Foley balloons' tamponade is an effective method for controlling massive pelvic bleeding during colorectal surgery.

Authors:  Tzu-Chi Hsu
Journal:  Ann Coloproctol       Date:  2022-01-24
  1 in total