Literature DB >> 9353476

Wallstent deployment to salvage dialysis graft thrombolysis complicated by venous rupture: early and intermediate results.

B Funaki1, G X Szymski, J A Leef, J D Rosenblum, R Burke, C A Hackworth.   

Abstract

OBJECTIVE: The feasibility of deploying Wallstents to treat venous rupture occurring during dialysis graft thrombolysis was determined. SUBJECTS AND METHODS: Between June 24, 1994, and February 19, 1997, 23 patients with venous rupture attributed to balloon angioplasty during dialysis graft thrombolysis were treated by Wallstent deployment across the area of rupture. Twenty-one ruptures occurred in peripheral veins and two occurred in central veins. Follow-up was provided by the clinical service at our institution and by electronic review of patients' charts.
RESULTS: Stent placement allowed completion of graft thrombolysis in all 23 patients. Complications were limited to four moderate-sized hematomas of the arm, and a single pseudoaneurysm developed 6 months after stent placement in one 27-year-old patient. The primary patency rate of stents was 52% at 60 days, 26% at 180 days, and 11% at 360 days. The secondary patency rate was 74% at 60 days, 65% at 180 days, and 56% at 360 days.
CONCLUSION: Treatment of venous ruptures using Wallstents is a safe alternative to intentional graft thrombosis. The patency rates of these devices are similar to those of venous stents placed for other indications.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9353476     DOI: 10.2214/ajr.169.5.9353476

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  11 in total

1.  Endovascular uncovered Wallstent placement for life-threatening isolated iliac vein injury caused by blunt pelvic trauma.

Authors:  Keitaro Sofue; Koji Sugimoto; Takeki Mori; Shinichi Nakayama; Masato Yamaguchi; Kazuro Sugimura
Journal:  Jpn J Radiol       Date:  2012-07-03       Impact factor: 2.374

2.  Problematic declots: complications and irritations.

Authors:  Brian Funaki
Journal:  Semin Intervent Radiol       Date:  2004-06       Impact factor: 1.513

Review 3.  A practical review of the use of stents for the maintenance of hemodialysis access.

Authors:  Michael Ginsburg; Jonathan M Lorenz; Sean P Zivin; Steven Zangan; Don Martinez
Journal:  Semin Intervent Radiol       Date:  2015-06       Impact factor: 1.513

4.  Endovascular management of immediate procedure-related complications of failed hemodialysis access recanalization.

Authors:  Dong Hun Kim; Dong Erk Goo; Seung Boo Yang; Cheul Moon; Deuk Lin Choi
Journal:  Korean J Radiol       Date:  2005 Jul-Sep       Impact factor: 3.500

5.  Use of stents for the maintenance of hemodialysis access.

Authors:  Jonathan M Lorenz
Journal:  Semin Intervent Radiol       Date:  2004-06       Impact factor: 1.513

6.  Delayed presentation of rupture after venous angioplasty.

Authors:  Matthew Backer; Steven Zangan
Journal:  Semin Intervent Radiol       Date:  2007-09       Impact factor: 1.513

7.  Axillary vein rupture after angioplasty.

Authors:  Carl N Valentin; Steven M Zangan
Journal:  Semin Intervent Radiol       Date:  2009-09       Impact factor: 1.513

8.  Treatment of hemodialysis vascular access rupture irresponsive to prolonged balloon tamponade: retrospective evaluation of the effectiveness of N-butyl cyanoacrylate seal-off technique.

Authors:  Mei-Jui Weng; Matt Chiung-Yu Chen; Huei-Lung Liang; Huay-Ben Pan
Journal:  Korean J Radiol       Date:  2012-12-28       Impact factor: 3.500

9.  Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting.

Authors:  J Y Ahn; Y S Chung; B H Lee; O J Kim
Journal:  Neuroradiology       Date:  2003-07-03       Impact factor: 2.804

10.  Metallic stent placement in hemodialysis graft patients after insufficient balloon dilation.

Authors:  Huei-Lung Liang; Huay-Ben Pan; Yih-Huie Lin; Chiung-Yu Chen; Hsiao-Min Chung; Tung-Ho Wu; Kang-Ju Chou; Pin-Hong Lai; Chien-Fang Yang
Journal:  Korean J Radiol       Date:  2006 Apr-Jun       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.