Literature DB >> 9352235

Multicentric reference values: shared reference limits.

M Ferré-Masferrer1, X Fuentes-Arderiu, V Alvarez-Funes, R Güell-Miró, M J Castiñeiras-Lacambra.   

Abstract

In order to obtain shared reference limits, three laboratories in the same geographical area with a homogeneous population have developed a proposal to produce multicentric reference values. The strategy simulates a virtual laboratory, actually formed by the laboratories involved; the reference limits produced in the virtual laboratory are in fact derived from the blend of reference values obtained by each laboratory. Each laboratory has chosen its own reference sample and has measured the biochemical quantities under study. Reference individuals (n = 171) and 15 biochemical quantities among the most measured in clinical laboratories were selected. The reference values obtained in each laboratory were blended when permitted by the Harris & Boyd test (Clin Chem 1990; 36:265-70). The multicentric reference limits obtained by the virtual laboratory for each quantity were estimated according to the recommendations of the International Federation of Clinical Chemistry. For each quantity, each laboratory, with the results observed in their reference sample, estimated the diagnostic specificity, using as cut-off values the corresponding multicentric reference limits. Each observed value of diagnostic specificity was compared with the theoretical diagnostic specificity value, equal to 0.975, that should be observed when a reference limit is used as cut-off value. The multicentric reference limits obtained by the virtual laboratory are valid in all cases with the exception of the upper reference limit for the concentrations of calcium(II) and urate in serum in one of the laboratories.

Entities:  

Mesh:

Year:  1997        PMID: 9352235

Source DB:  PubMed          Journal:  Eur J Clin Chem Clin Biochem        ISSN: 0939-4974


  3 in total

1.  Prerequisites for use of common reference intervals.

Authors:  Ferruccio Ceriotti
Journal:  Clin Biochem Rev       Date:  2007-08

2.  The case for common reference intervals.

Authors:  Graham R D Jones; Antony Barker; Jill Tate; Chen-Fee Lim; Ken Robertson
Journal:  Clin Biochem Rev       Date:  2004-05

Review 3.  Advances in Pediatric Reference Intervals for Biochemical Markers: Establishment of the Caliper Database in Healthy Children and Adolescents.

Authors:  Kimiya Karbasy; Petra Ariadne; Stephanie Gaglione; Michelle Nieuwesteeg; Khosrow Adeli
Journal:  J Med Biochem       Date:  2014-10-08       Impact factor: 3.402

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.