Literature DB >> 9350745

Performance of the Amplicor human immunodeficiency virus type 1 PCR and analysis of specimens with false-negative results.

K L Barlow1, J H Tosswill, J V Parry, J P Clewley.   

Abstract

Over a 4-year period, the Roche Amplicor kit was used in a United Kingdom reference laboratory for the detection or confirmation of human immunodeficiency virus (HIV) type 1 infection, particularly in infants born to HIV-infected mothers. Of 408 specimens from adults and older children tested, the 122 seronegative specimens were all Amplicor negative. Of the 286 seropositive specimens, 268 were Amplicor positive. On the basis of these results, the Amplicor assay has a specificity of 100% and a sensitivity of 93.7%. In addition, for 247 specimens from infants and young children, serological results may not have been diagnostic because of placental transfer of maternal antibodies. Forty-eight were Amplicor positive, and of the 199 Amplicor-negative specimens, 19 were assumed to be false negative on the basis of clinical data, serological markers (including p24 antigen), and/or results for previous or follow-up specimens. This represents a sensitivity of 75% for the Amplicor test for specimens from patients under 2 years of age. Of these 37 false-negative specimens plus 2 specimens from other laboratories, 31 could be characterized by amplifying extracted material from them by an in-house nested gag PCR spanning the Amplicor target region. The amplicons were sequenced and found to represent subtypes A (35.5%), B (22.6%), C (22.6%), D (16.1%), and G (3.2%). False-negative results by the Amplicor assay may be ascribed to low-target copy number, the physical behavior of one primer (SK462), and sequence variation in the target region of the other primer (SK431).

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9350745      PMCID: PMC230073          DOI: 10.1128/jcm.35.11.2846-2853.1997

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  25 in total

1.  A simple and rapid method for detecting human immunodeficiency virus by PCR.

Authors:  K M Gibson; K A McLean; J P Clewley
Journal:  J Virol Methods       Date:  1991-05       Impact factor: 2.014

2.  Genetic variability affects the detection of HIV by polymerase chain reaction.

Authors:  D Candotti; M Jung; D Kerouedan; M Rosenheim; M Gentilini; P M'Pele; J M Huraux; H Agut
Journal:  AIDS       Date:  1991-08       Impact factor: 4.177

3.  Diverse HIV-1 genetic subtypes in UK.

Authors:  J P Clewley; C Arnold; K L Barlow; P R Grant; J V Parry
Journal:  Lancet       Date:  1996-05-25       Impact factor: 79.321

4.  Predicting DNA duplex stability from the base sequence.

Authors:  K J Breslauer; R Frank; H Blöcker; L A Marky
Journal:  Proc Natl Acad Sci U S A       Date:  1986-06       Impact factor: 11.205

5.  Genetic diversity and HIV detection by polymerase chain reaction.

Authors:  I Loussert-Ajaka; D Descamps; F Simon; F Brun-Vézinet; M Ekwalanga; S Saragosti
Journal:  Lancet       Date:  1995-09-30       Impact factor: 79.321

6.  Low human immunodeficiency virus type 1 (HIV-1) DNA burden as a major cause for failure to detect HIV-1 DNA in clinical specimens by PCR.

Authors:  M Zazzi; L Romano; M Catucci; A De Milito; P Almi; A Gonnelli; M Rubino; P E Valensin
Journal:  J Clin Microbiol       Date:  1995-01       Impact factor: 5.948

7.  Comparison of a rapid nonisotopic polymerase chain reaction assay with four commonly used methods for the early diagnosis of human immunodeficiency virus type 1 infection in neonates and children.

Authors:  A Kovacs; J Xu; S Rasheed; X L Li; T Kogan; M Lee; C Liu; L Chan
Journal:  Pediatr Infect Dis J       Date:  1995-11       Impact factor: 2.129

8.  Detection of HIV-1 sequences in children using radioactive and colorimetric polymerase chain reactions.

Authors:  A A Giri; F B Lillo; J L McDermott; C Jannuzzi; S Risso; G L Fornia; D R Concedi; O E Varnier
Journal:  J Med Virol       Date:  1994-04       Impact factor: 2.327

9.  Rapid screening for early detection of mother-to-child transmission of human immunodeficiency virus type 1.

Authors:  S Cassol; A Butcher; S Kinard; J Spadoro; T Sy; N Lapointe; S Read; P Gomez; M Fauvel; C Major
Journal:  J Clin Microbiol       Date:  1994-11       Impact factor: 5.948

10.  Early diagnosis of perinatal HIV infection by detection of viral-specific IgA antibodies.

Authors:  T C Quinn; R L Kline; N Halsey; N Hutton; A Ruff; A Butz; R Boulos; J F Modlin
Journal:  JAMA       Date:  1991-12-25       Impact factor: 56.272

View more
  11 in total

1.  env Gene typing of human immunodeficiency virus type 1 strains on electronic microarrays.

Authors:  N A Saunders; S Alexander; I Tatt
Journal:  J Clin Microbiol       Date:  2005-04       Impact factor: 5.948

2.  Multicenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity.

Authors:  Bernard Weber; Lutz Gürtler; Rigmor Thorstensson; Ulrike Michl; Annelies Mühlbacher; Philippe Bürgisser; Roberto Villaescusa; Adolfo Eiras; Christian Gabriel; Herbert Stekel; Srivilai Tanprasert; Sinenaart Oota; Maria-Jose Silvestre; Cristina Marques; Maria Ladeira; Holger Rabenau; Annemarie Berger; Urban Schmitt; Walter Melchior
Journal:  J Clin Microbiol       Date:  2002-06       Impact factor: 5.948

3.  Evaluation of a new combined antigen and antibody human immunodeficiency virus screening assay, VIDAS HIV DUO Ultra.

Authors:  Bernard Weber; Annemarie Berger; Holger Rabenau; Hans Wilhelm Doerr
Journal:  J Clin Microbiol       Date:  2002-04       Impact factor: 5.948

4.  Early HIV-1 diagnosis using in-house real-time PCR amplification on dried blood spots for infants in remote and resource-limited settings.

Authors:  Nicole Ngo-Giang-Huong; Woottichai Khamduang; Baptiste Leurent; Intira Collins; Issaren Nantasen; Pranee Leechanachai; Wasna Sirirungsi; Aram Limtrakul; Tasana Leusaree; Anne Marie Comeau; Marc Lallemant; Gonzague Jourdain
Journal:  J Acquir Immune Defic Syndr       Date:  2008-12-15       Impact factor: 3.731

5.  RT-PCR detection of HIV in Republic of Macedonia.

Authors:  Golubinka Bosevska; Nikola Panovski; Eleni Dokić; Violeta Grunevska
Journal:  Bosn J Basic Med Sci       Date:  2008-11       Impact factor: 3.363

6.  A novel simian immunodeficiency virus (SIVdrl) pol sequence from the drill monkey, Mandrillus leucophaeus.

Authors:  J P Clewley; J C Lewis; D W Brown; E L Gadsby
Journal:  J Virol       Date:  1998-12       Impact factor: 5.103

7.  Comparison of an amplified enzyme-linked immunosorbent assay with procedures based on molecular biology for assessing human immunodeficiency virus type 1 viral load.

Authors:  P L Goldschmidt; A Devillechabrolle; Z Ait-Arkoub; J T Aubin
Journal:  Clin Diagn Lab Immunol       Date:  1998-07

8.  Reduction of diagnostic window by new fourth-generation human immunodeficiency virus screening assays.

Authors:  B Weber; E H Fall; A Berger; H W Doerr
Journal:  J Clin Microbiol       Date:  1998-08       Impact factor: 5.948

9.  Evaluation of the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation compared with the ROCHE COBAS AmpliPrep/AMPLICOR HIV-1 MONITOR v1.5 using specimens from East Africa.

Authors:  John A Crump; Lesley E Scott; Emma Msuya; Anne B Morrissey; Ekyafyose E Kimaro; John F Shao; Wendy S Stevens
Journal:  J Virol Methods       Date:  2009-09-01       Impact factor: 2.014

10.  Expecting the unexpected: nucleic acid-based diagnosis and discovery of emerging viruses.

Authors:  Ross Thomas Barnard; Roy A Hall; Ernest A Gould
Journal:  Expert Rev Mol Diagn       Date:  2011-05       Impact factor: 5.225

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.