Literature DB >> 9350713

Evaluation of a cassette-screen-film combination for radiation therapy portal localization imaging with improved contrast.

A G Haus1, R E Dickerson, K E Huff, S Monte, B A Schlager, M Atanas, A Matloubieh.   

Abstract

A traditional limitation with radiation therapy portal images is low image contrast, due in part to the low attenuation of the exposing radiation by the tissues being imaged, and the contrast capabilities of the image receptor. We have developed, and have clinically evaluated, a cassette-screen-film combination for portal localization imaging, which features a copper front screen plus Gd2O2S:Tb fluorescent screens and a slow-speed, fine grain, film emulsion with inherently high contrast coated on both sides of a 7 mil Estar base. The film can be processed in a conventional rapid-process film processor. Sensitometric data indicate that the film contrast (average gradient) for the new combination is approximately 3.5 times higher than the conventional portal localization systems in current use. The new combination has been clinically compared with two conventional systems. The required monitor unit settings were found to be similar. Initial clinical results indicate portal images made with the new combination are superior to those obtained with the conventional combinations. The images have much higher contrast, subjective impressions of lower noise, show clearer definition of structures, and are much easier to read.

Entities:  

Mesh:

Year:  1997        PMID: 9350713     DOI: 10.1118/1.597979

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Comparison of four commercial devices for RapidArc and sliding window IMRT QA.

Authors:  Varatharaj Chandraraj; Sotirios Stathakis; Ravikumar Manickam; Carlos Esquivel; Sanjay S Supe; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2011-04-04       Impact factor: 2.102

2.  Development of a dose verification system for Vero4DRT using Monte Carlo method.

Authors:  Yoshitomo Ishihara; Akira Sawada; Mitsuhiro Nakamura; Yuki Miyabe; Hiroaki Tanabe; Shuji Kaneko; Kenji Takayama; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

3.  Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases.

Authors:  Mohsen Saeb; Daryoush Shahbazi-Gahrouei; Shahram Monadi
Journal:  J Med Signals Sens       Date:  2018 Apr-Jun
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.