Literature DB >> 9349889

The outcome of Austin-Moore hemiarthroplasty for fracture of the femoral neck.

M Clayer1, J Bruckner.   

Abstract

One hundred and fifty-four consecutive patients who sustained a fracture of the femoral neck and were treated with an Austin-Moore hemiarthroplasty were followed up longitudinally for 10 years, or until revision of the prosthesis, or death of the patient. Clinical assessments were performed at 1, 3, 5, and 10 years after surgery. At 3 years, 46% of the patients were community ambulators; 10%, household ambulators; 6%, nonfunctional ambulators; 29%, nonambulators; and 9% unknown. At 10 years, 31% were community ambulators; 35%, household ambulators; 4%, nonfunctional ambulators; and 30%, nonambulators. Men had statistically significantly better ambulation than women at the 3-year review (P = 0.004), but there was no difference at later assessments. The Harris hip score was 69 (range, 41 to 97) at 5 years and 69 (range, 25 to 90) at 10 years. The overall failure rate was 6.5% at 5 years and 7.7% at 10 years. The revision rate was 4.5% at 5 years and 5.2% at 10 years. Patients younger than 70 years at the time of fracture had a statistically significantly higher revision rate than did older patients.

Entities:  

Mesh:

Year:  1997        PMID: 9349889

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  6 in total

1.  Outcome of treatment of fracture neck of femur using hemiarthroplasty versus dynamic hip screw.

Authors:  Dd Mue; Mn Salihu; F0 Awonusi; Wt Yongu; Jn Kortor; Ic Elachi
Journal:  J West Afr Coll Surg       Date:  2013-04

2.  A cost-effectiveness analysis of the arthroplasty options for displaced femoral neck fractures in the active, healthy, elderly population.

Authors:  James Slover; Michael V Hoffman; Henrik Malchau; Anna N A Tosteson; Kenneth J Koval
Journal:  J Arthroplasty       Date:  2008-08-12       Impact factor: 4.757

3.  Total hip arthroplasty for failed aseptic Austin Moore prosthesis.

Authors:  Pradeep Bhosale; Ashish Suryawanshi; Amber Mittal
Journal:  Indian J Orthop       Date:  2012-05       Impact factor: 1.251

4.  Results of Conversion from Failed Austin-Moore Hemiarthroplasty to Cementless Total Hip Arthroplasty in Octogenarian Patients with Advanced Acetabular Erosion: A Minimum of 5 Years of Follow-Up.

Authors:  Tsan-Wen Huang; Chih-Hsiang Chang; Fu-Chun Chang; Chun-Chieh Chen; Kuo-Chin Huang; Mel S Lee; Hsin-Nung Shih
Journal:  Biomed Res Int       Date:  2019-04-02       Impact factor: 3.411

5.  Conversion of failed hemiarthroplasty to total hip arthroplasty: a short to mid-term follow-up study.

Authors:  Amite Pankaj; Rajesh Malhotra; Surya Bhan
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

6.  Total Hip Arthroplasty in a Girdlestone Hip following a Failed Hemiarthroplasty.

Authors:  V J Purushotham; B T Ranganath
Journal:  J Orthop Case Rep       Date:  2015 Apr-Jun
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.