OBJECTIVE: To compare the results of a 1990 College of American Pathologists Q-Probes Emergency Department (ED) turnaround time (TAT) study with a similar study done in 1993 and to identify factors associated with TAT improvement.
DESIGN: Participants gathered data over a 4-week period on the various times of day associated with the ordering, specimen-collection, laboratory-receipt, and result-reporting stages of stat tests for potassium and hemoglobin levels, using a mail-in questionnaire that also included practice parameter questions. PARTICIPANTS: Laboratories enrolled in the 1990 College of American Pathologists Q-Probes study on ED TAT and laboratories enrolled in the 1993 program ED TAT study. MAIN OUTCOME MEASURES: Components associated with shorter ED TAT and, for those participating in both the 1990 and 1993 studies, comparison with previous results.
RESULTS: Six hundred fifteen hospital laboratories returned data on up to 43,521 hemoglobin and 41,989 potassium specimens. Half of these laboratories collected and reported 90% of their ED potassium results in 53 minutes or less, compared to 61 minutes or less in 1990, and reduced the corresponding median collection-to-reporting TAT for 90% of hemoglobin results from 46 minutes or less to 39 minutes or less. The fastest 10% of laboratories showed interlaboratory median order-to-report TATs of 36 and 50 minutes for potassium and hemoglobin tests, respectively. Comparisons of TATs from 277 laboratories with 1990 and 1993 data were possible. Components found to contribute statistically to improvement of ED TAT between 1990 and 1993 were laboratory control of specimen handling, rapid transport time, and monitoring. Active monitoring was particularly important when the laboratory did not control the specimen-handling process.
CONCLUSIONS: Laboratories improved their control of ED TAT from 1990 to 1993 and reduced the number of TAT events exceeding 70 minutes. Internally set TAT goals, however, were not met most of the time.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9341581

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  6 in total

1.  Dutch guideline on the laboratory detection of methicillin-resistant Staphylococcus aureus.

Authors:  M F Q Kluytmans-van den Bergh; M C Vos; B M W Diederen; C M J E Vandenbroucke-Grauls; A Voss; J A J W Kluytmans
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-07-27       Impact factor: 3.267

2.  Laboratory turnaround time.

Authors:  Robert C Hawkins
Journal:  Clin Biochem Rev       Date:  2007-11

3.  National survey on turnaround time of clinical biochemistry tests in 738 laboratories in China.

Authors:  Xiaoyan Zhang; Yang Fei; Wei Wang; Haijian Zhao; Minqi Wang; Bingquan Chen; Jie Zhou; Zhiguo Wang
Journal:  J Clin Lab Anal       Date:  2017-05-11       Impact factor: 2.352

Review 4.  Mapping turnaround times (TAT) to a generic timeline: a systematic review of TAT definitions in clinical domains.

Authors:  Bernhard Breil; Fleur Fritz; Volker Thiemann; Martin Dugas
Journal:  BMC Med Inform Decis Mak       Date:  2011-05-24       Impact factor: 2.796

5.  Therapeutic turnaround times for common laboratory tests in a tertiary hospital in Kenya.

Authors:  Thomas Mwogi; Tim Mercer; Dan N Tina Tran; Ronald Tonui; Thorkild Tylleskar; Martin C Were
Journal:  PLoS One       Date:  2020-04-08       Impact factor: 3.240

6.  Effectiveness of a Mobile App in Reducing Therapeutic Turnaround Time and Facilitating Communication between Caregivers in a Pediatric Emergency Department: A Randomized Controlled Pilot Trial.

Authors:  Frederic Ehrler; Carlotta Tuor; Remy Trompier; Antoine Berger; Michael Ramusi; Robin Rey; Johan N Siebert
Journal:  J Pers Med       Date:  2022-03-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.