Theoretical study of the effects of tooth and implant mobility differences on occlusal force transmission in tooth/implant-supported partial prostheses.

R Kayacan1, R Ballarini, R L Mullen.   

Abstract

STATEMENT OF PROBLEM: Despite their mobility differences under occlusal loads, a natural tooth and an implant are often used together to support fixed prostheses. In some situations, tooth/implant-supported partial prostheses include cantilever extensions, especially in the posterior region where the bone is inadequate for placement of an additional implant.
PURPOSE: In this study, engineering beam theory was used to study the effects of the mobility differences between the implant and the tooth on the force and moment distribution, due to occlusal loads in tooth/implant-supported prostheses.
METHODS: The prosthesis was treated as a linear elastic beam and the supports were modeled as springs with (vertical) translational and rotational stiffness. The bending moments and forces on the supports were calculated as functions of the parameters that describe the geometry, position of the occlusal load, and stiffness ratios (namely, implant or tooth) of the springs.
RESULTS: Bending moments on the supports were more sensitive to the relative rotational mobility between the supports and their individual values than to the relative translational mobility. The moment at the implant was minimized when the supports had similar mobilities. A preliminary design concept was introduced and eliminated the moment at the implant without significantly increasing the magnitude of the moment at the tooth. Cantilevering the prosthesis resulted in moderately increased bending moments and considerable tensile forces on the supports for a broad range of the parameters that describe the geometry and loading.
CONCLUSIONS: From this simulation, it is suggested that cantilever extensions should be avoided or supported by a short implant, which will only restrain the vertical movement of the cantilever end.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9338871     DOI: 10.1016/s0022-3913(97)70047-7

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Rationale for tilted implants: FEA considerations and clinical reports.

Authors:  G DE Vico; M Bonino; D Spinelli; R Schiavetti; G Sannino; A Pozzi; L Ottria
Journal:  Oral Implantol (Rome)       Date:  2012-04-15

2.  Fracture Resistance of Composite Fixed Partial Dentures Reinforced with Pre-impregnated and Non-impregnated Fibers.

Authors:  Ramin Mosharraf; Sepideh Torkan
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2012-03-13

Review 3.  Combined Implant and Tooth Support: An Up-to-Date Comprehensive Overview.

Authors:  Mahmoud K Al-Omiri; Maher Al-Masri; Mohannad M Alhijawi; Edward Lynch
Journal:  Int J Dent       Date:  2017-03-23

Review 4.  Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives.

Authors:  Elisabetta M Zanetti; Giulia Pascoletti; Michele Calì; Cristina Bignardi; Giordano Franceschini
Journal:  Biosensors (Basel)       Date:  2018-07-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.