Literature DB >> 9337028

The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system.

G H Clayton1, C F Driscoll, S O Hondrum.   

Abstract

In this study, various luting agents were evaluated to determine their retentive strengths as they pertain to the CeraOne single-tooth implant system. Ten samples of five different luting agents (zinc oxide-eugenol, glass-ionomer cement, hybrid glass-ionomer cement, composite resin, and zinc phosphate) were tested for retentive strength of the CeraOne gold cylinder to the CeraOne abutment. Under the conditions of the experiment, zinc phosphate showed a mean retentive strength 164% greater than that of glass-ionomer cement and 49% greater than that of composite resin cement. Scanning electron micrographs were taken to evaluate the effect of various luting agents on marginal opening. The measurements revealed that zinc phosphate had the greatest marginal opening, although its mean value of 62 microns is within clinically acceptable limits.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9337028

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  10 in total

1.  Dimensional Accuracy of Castings Fabricated with Ring-less and Metal Ring Investment Systems for Implant Supported Fixed Dental Prosthesis: An In-vitro Comparative Study.

Authors:  Rakesh Shah; J P Singh; Manjit Kumar; Dsj D'Souza
Journal:  Med J Armed Forces India       Date:  2011-07-21

2.  Clinician- and patient-reported long-term evaluation of screw- and cement-retained implant restorations: a 5-year prospective study.

Authors:  Sami Sherif; Srinivas M Susarla; Jae-Woong Hwang; Hans-Peter Weber; Robert F Wright
Journal:  Clin Oral Investig       Date:  2010-09-01       Impact factor: 3.573

3.  The selection criteria of temporary or permanent luting agents in implant-supported prostheses: in vitro study.

Authors:  Angel Alvarez-Arenal; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Aritza Brizuela-Velasco; Joseba Ellacuria-Echebarria
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

4.  Effect of Abutment Height on Retention of Single Cement-retained, Wide- and Narrow-platform Implant-supported Restorations.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Sara Nuroloyuni; Sohleh Khodabakhsh; Mehran Bahrami; Reza Nahidi; Somaieh Zeighami
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2012-09-01

5.  Retentiveness of implant-supported metal copings using different luting agents.

Authors:  Farahnaz Nejatidanesh; Omid Savabi; Maziar Ebrahimi; Ghazal Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-01

6.  Effect of Surface Modifications on the Retention of Cement-retained Implant Crowns under Fatigue Loads: An In vitro Study.

Authors:  R Ajay; K Suma; Seyed Asharaf Ali; Jambai Sampath Kumar Sivakumar; V Rakshagan; V Devaki; K Divya
Journal:  J Pharm Bioallied Sci       Date:  2017-11

7.  Digital versus conventional techniques for pattern fabrication of implant-supported frameworks.

Authors:  Marzieh Alikhasi; Ahmad Rohanian; Safoura Ghodsi; Amin Mohammadpour Kolde
Journal:  Eur J Dent       Date:  2018 Jan-Mar

8.  Retention of Various Luting Agents Used with Implant-Supported Crowns.

Authors:  Santhosh Sathyanarayan; Tamizhesai Balavadivel; Rakshit C Guru; Abhijeet Rajendra Sande; Venkateswaran Rajendran; Arul Kumar Sengottaiyan
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10

9.  Retention Strength after Compressive Cyclic Loading of Five Luting Agents Used in Implant-Supported Prostheses.

Authors:  Angel Alvarez-Arenal; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Aritza Brizuela-Velasco; Javier Pinés-Hueso; Joseba Ellakuria-Echebarria
Journal:  Biomed Res Int       Date:  2016-10-16       Impact factor: 3.411

10.  Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation.

Authors:  Monica Shrivastav
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.