Increased incidence of sighs (augmented inspiratory efforts) during synchronized intermittent mandatory ventilation (SIMV) in preterm neonates.

H Hummler1, T Gerhardt, A Gonzalez, N Claure, R Everett, E Bancalari.   

Abstract

A reflex resulting in a deep, sigh-like inspiratory effort (augmented breath) is frequently triggered during synchronized mechanical ventilation in preterm infants. We studied the incidence of augmented inspiratory efforts and their effect on ventilation and lung compliance during conventional IMV and synchronized IMV (SIMV) in 15 preterm neonates (GA 26.7 +/- 1.5 wks (mean +/- SD), BW 925 +/- 222 g, age 1-8 days). Augmentation of spontaneous inspiratory effort was defined as an esophageal pressure deflection occurring coincident with a synchronized mechanical breath and exceeding the previous unassisted spontaneous effort by more than 50%. The incidence of augmented breaths was higher during SIMV (11.1 +/- 7.7%; P < 0.01) than during conventional IMV (5.1 +/- 6.1%). However, when the synchronized breaths were triggered late (200-300 msec) after the onset of inspiration, augmented breaths occurred no more frequently than during conventional IMV (6.0 +/- 4.7%). The incidence of augmented breaths correlated inversely with dynamic lung compliance (P = 0.014), but was not significantly influenced by a change in PEEP. Although inspiratory effort increased nearly three times during the augmented breaths, tidal volume increased only 12%. The change in tidal volume was limited because the augmented effort reached its maximal negativity only approximately 500 ms after the beginning of the synchronized, mechanical breath and at a time when the mechanical breath had already ended. For this reason the augmented effort did not contribute significantly to minute ventilation, but only prolonged inspiration. Dynamic lung compliance did not change significantly after an augmented breath. The results indicate that augmented inspiratory efforts are more common in preterm neonates ventilated with SIMV than with conventional IMV, but do not contribute significantly to ventilation.

Entities:  

Mesh:

Year:  1997        PMID: 9330416     DOI: 10.1002/(sici)1099-0496(199709)24:3<195::aid-ppul5>3.0.co;2-m

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  3 in total

1.  Emergence of sigh rhythmogenesis in the embryonic mouse.

Authors:  Coralie Chapuis; Sandra Autran; Gilles Fortin; John Simmers; Muriel Thoby-Brisson
Journal:  J Physiol       Date:  2014-03-03       Impact factor: 5.182

2.  The effect of sigh on cardiorespiratory synchronization in healthy sleeping infants.

Authors:  Chinh D Nguyen; Carolyn Dakin; Margaret Yuill; Stuart Crozier; Stephen Wilson
Journal:  Sleep       Date:  2012-12-01       Impact factor: 5.849

Review 3.  Synchronized mechanical ventilation for respiratory support in newborn infants.

Authors:  Anne Greenough; Thomas E Rossor; Adesh Sundaresan; Vadivelam Murthy; Anthony D Milner
Journal:  Cochrane Database Syst Rev       Date:  2016-09-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.