| Literature DB >> 9327609 |
G Sparacino1, P Vicini, R Bonadonna, P Marraccini, M Lehtovirta, E Ferrannini, C Cobelli.
Abstract
The study of blood-tissue exchange by the multiple indicator dilution technique often needs frequent sampling in the blood of the indicator dilution curves (IDC). Usually, this requires the use of a catheter supported by a pump. This causes a distortion in the IDC, which must be removed for proper interpretation of the data. A deconvolution-based methodology to remove IDC distortion is presented. First, the catheter impulse response is modelled by means of data obtained from a suitable experiment. Then the reconstruction of the blood IDC is tackled by a new nonparametric deconvolution algorithm, which provides (quasi) time-continuous signals and exploits statistically based criteria for the choice of the regularisation parameter. The methodology is applied to the removal of catheter distortion in studies of glucose blood-tissue exchange in the human forearm and myocardium.Entities:
Mesh:
Substances:
Year: 1997 PMID: 9327609 DOI: 10.1007/bf02534087
Source DB: PubMed Journal: Med Biol Eng Comput ISSN: 0140-0118 Impact factor: 2.602