Literature DB >> 9327606

Non-invasive determination of instantaneous heart rate in developing avian embryos by means of acoustocardiogram.

R Akiyama1, H Ono, J Höchel, J T Pearson, H Tazawa.   

Abstract

Previous noninvasive studies of the mean heart rate of embryonic birds have prompted an investigation into the instantaneous heart rate (IHR), which may be informative in developmental studies of cardiac rhythm. Using the acoustocardiogram (ACG), a noninvasive, long-term measuring system for embryonic IHR is developed, and the IHR in chickens during the last half of embryonic development is determined. The system, which uses a micro-computer, samples the ACG at a frequency of 50 Hz, restores the ACG wave by sinc function and calculates the IHR with an error in accuracy of less than 1 beat min-1. It was found that characteristic, transient bradycardia begins to appear late in the second week of incubation, and, with the additional development of transient tachycardia, the embryonic cardiac rhythm becomes more arrhythmic towards hatching. Simultaneous measurements of IHR with somatic movements showed no relationship between arrhythmia and embryonic activities. This system is useful, providing new evidence on long-term IHR developmental patterns.

Entities:  

Mesh:

Year:  1997        PMID: 9327606     DOI: 10.1007/bf02534084

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  17 in total

1.  Gas exchange across avian eggshells oscillates in phase with heartbeat.

Authors:  N Wang; J P Butler; R B Banzett
Journal:  J Appl Physiol (1985)       Date:  1990-10

2.  Noninvasive heart rate monitoring system for avian embryos based on the ballistocardiogram.

Authors:  Y Suzuki; H Musashi; H Tazawa
Journal:  Med Biol Eng Comput       Date:  1989-07       Impact factor: 2.602

3.  Simultaneous acquisition of ECG, BCG, and blood pressure from chick embryos in the egg.

Authors:  H Tazawa; Y Suzuki; H Musashi
Journal:  J Appl Physiol (1985)       Date:  1989-07

4.  Arterial pressure in the chick embryo.

Authors:  H Girard
Journal:  Am J Physiol       Date:  1973-02

5.  A method for noninvasive, long-term recording of the avian embryo heart rate.

Authors:  R Pirow; R Bilsing; M Nichelmann; J Höchel
Journal:  Physiol Behav       Date:  1995-07

6.  Measurement of blood pressure of chick embryo with an implanted needle catheter.

Authors:  H Tazawa
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1981-10

7.  Development of arterial blood pressure in the chick embryo.

Authors:  L H Van Mierop; C J Bertuch
Journal:  Am J Physiol       Date:  1967-01

8.  Heart rate of the developing chick embryo.

Authors:  J R Cain; U K Abbott; V L Rogallo
Journal:  Proc Soc Exp Biol Med       Date:  1967-11

9.  Comparisons between invasive and noninvasive determinations of embryonic heart rate in chickens.

Authors:  M A Haque; W Watanabe; H Ono; Y Sakamoto; H Tazawa
Journal:  Comp Biochem Physiol Comp Physiol       Date:  1994 Jun-Jul

10.  Repetitive and simultaneous sampling from the air cell and blood vessels in the chick embryo.

Authors:  H Tazawa; A Ar; H Rahn; J Piiper
Journal:  Respir Physiol       Date:  1980-03
View more
  1 in total

1.  Smartphone-Based Device for Non-Invasive Heart-Rate Measurement of Chicken Embryos.

Authors:  Akkachai Phuphanin; Lawan Sampanporn; Boonsong Sutapun
Journal:  Sensors (Basel)       Date:  2019-11-06       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.