Simultaneous delivery of two patent arterial duct coils via one venous sheath.

D De Wolf1, H Verhaaren, D Matthys.   

Abstract

A female child, 10 months of age, weighing 7.2 kg, was catheterised for closure of a patent arterial duct. Aortography was performed in the lateral projection and the minimum diameter of the arterial duct was assessed by comparing it to the size of the catheter. The duct size was estimated between 3 and 3.5 mm at the narrowest point, therefore, it was decided to deliver two 5 mm patent arterial duct coils to avoid placement of an 8 mm coil in this small child. Similar operations were subsequently performed in two further children. Simultaneous delivery of two coils via a single long venous sheath is easy, fast, and safe. This simple and inexpensive procedure can reduce irradiation and anaesthesia time.

Entities:  

Mesh:

Year:  1997        PMID: 9327000      PMCID: PMC484906          DOI: 10.1136/hrt.78.2.201

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  6 in total

1.  Closure of the arterial duct: past, present, and future.

Authors:  M L Rigby
Journal:  Heart       Date:  1996-12       Impact factor: 5.994

2.  Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils.

Authors:  A J Tometzki; R Arnold; I Peart; N Sreeram; J M Abdulhamed; M J Godman; R G Patel; D J Kitchiner; F A Bu'Lock; K P Walsh
Journal:  Heart       Date:  1996-12       Impact factor: 5.994

3.  Evolving use of embolisation coils for occlusion of the arterial duct.

Authors:  E Rosenthal; S A Qureshi; J Reidy; E J Baker; M Tynan
Journal:  Heart       Date:  1996-12       Impact factor: 5.994

4.  Total UK multi-centre experience with a novel arterial occlusion device (Duct Occlud pfm).

Authors:  A Tometzki; K Chan; J De Giovanni; A Houston; R Martin; D Redel; A Redington; M Rigby; J Wright; N Wilson
Journal:  Heart       Date:  1996-12       Impact factor: 5.994

5.  Transcatheter closure of large patent ductus arteriosus (> or = 4 mm) with multiple Gianturco coils: immediate and mid-term results.

Authors:  Z M Hijazi; R L Geggel
Journal:  Heart       Date:  1996-12       Impact factor: 5.994

6.  Transcatheter occlusion of the arterial duct with Cook detachable coils: early experience.

Authors:  O Uzun; S Hancock; J M Parsons; D F Dickinson; J L Gibbs