Literature DB >> 9322271

Infant polysomnography: reliability. Collaborative Home Infant Monitoring Evaluation (CHIME) Steering Committee.

D H Crowell1, L J Brooks, T Colton, M J Corwin, T T Hoppenbrouwers, C E Hunt, L E Kapuniai, G Lister, M R Neuman, M Peucker, S L Ward, D E Weese-Mayer, M Willinger.   

Abstract

Infant polysomnography (IPSG) is an increasingly important procedure for studying infants with sleep and breathing disorders. Since analyses of these IPSG data are subjective, an equally important issue is the reliability or strength of agreement among scorers (especially among experienced clinicians) of sleep parameters (SP) and sleep states (SS). One basic issue of this problem was examined by proposing and testing the hypothesis that infant SP and SS ratings can be reliably scored at substantial levels of agreement, that is, kappa (kappa) > or = 0.61. In light of the importance of IPSG reliability in the collaborative home infant monitoring evaluation (CHIME) study, a reliability training and evaluation process was developed and implemented. The bases for training on SP and SS scoring were CHIME criteria that were modifications and supplements to Anders, Emde, and Parmelee (10). The kappa statistic was adopted as the method for evaluating reliability between and among scorers. Scorers were three experienced investigators and four trainees. Inter- and intrarater reliabilities for SP codes and SSs were calculated for 408 randomly selected 30-second epochs of nocturnal IPSG recorded at five CHIME clinical sites from healthy full term (n = 5), preterm (n = 4), apnea of infancy (n = 2), and siblings of the sudden infant death syndrome (SIDS) (n = 4) enrolled subjects. Infant PSG data set 1 was scored by both experienced investigators and trained scorers and was used to assess initial interrater reliability. Infant PSG data set 2 was scored twice by the trained scorers and was used to reassess inter-rater reliability and to assess intrarater reliability. The kappa s for SS ranged from 0.45 to 0.58 for data set 1 and represented a moderate level of agreement. Therefore, rater disagreements were reviewed, and the scoring criteria were modified to clarify ambiguities. The kappa s and confidence intervals (CIs) computed for data set 2 yielded substantial inter-rater and intrarater agreements for the four trained scorers; for SS, the kappa = 0.68 and for SP the kappa s ranged from 0.62 to 0.76. Acceptance of the hypothesis supports the conclusion that the IPSG is a reliable source of clinical and research data when supported by significant kappa s and CIs. Reliability can be maximized with strictly detailed scoring guidelines and training.

Entities:  

Mesh:

Year:  1997        PMID: 9322271

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  18 in total

1.  Is SIDS associated with sleep? : A report of six cases demonstrating difficulty in this determination.

Authors:  Henry F Krous; Amy E Chadwick; Christina Stanley; J Bruce Beckwith
Journal:  Forensic Sci Med Pathol       Date:  2005-09       Impact factor: 2.007

Review 2.  A review of signals used in sleep analysis.

Authors:  A Roebuck; V Monasterio; E Gederi; M Osipov; J Behar; A Malhotra; T Penzel; G D Clifford
Journal:  Physiol Meas       Date:  2013-12-17       Impact factor: 2.833

3.  Non-invasive monitoring of chewing and swallowing for objective quantification of ingestive behavior.

Authors:  Edward Sazonov; Stephanie Schuckers; Paulo Lopez-Meyer; Oleksandr Makeyev; Nadezhda Sazonova; Edward L Melanson; Michael Neuman
Journal:  Physiol Meas       Date:  2008-04-22       Impact factor: 2.833

4.  Developmental profiles of infant EEG: overlap with transient cortical circuits.

Authors:  M M Myers; P G Grieve; A Izraelit; W P Fifer; J R Isler; R A Darnall; R I Stark
Journal:  Clin Neurophysiol       Date:  2012-02-17       Impact factor: 3.708

5.  Application of recurrence quantification analysis to automatically estimate infant sleep states using a single channel of respiratory data.

Authors:  Philip I Terrill; Stephen J Wilson; Sadasivam Suresh; David M Cooper; Carolyn Dakin
Journal:  Med Biol Eng Comput       Date:  2012-05-22       Impact factor: 2.602

Review 6.  Executive summary of respiratory indications for polysomnography in children: an evidence-based review.

Authors:  Merrill S Wise; Cynthia D Nichols; Madeleine M Grigg-Damberger; Carole L Marcus; Manisha B Witmans; Valerie G Kirk; Lynn A D'Andrea; Timothy F Hoban
Journal:  Sleep       Date:  2011-03-01       Impact factor: 5.849

7.  Deep learning in the cross-time frequency domain for sleep staging from a single-lead electrocardiogram.

Authors:  Qiao Li; Qichen Li; Chengyu Liu; Supreeth P Shashikumar; Shamim Nemati; Gari D Clifford
Journal:  Physiol Meas       Date:  2018-12-21       Impact factor: 2.833

8.  An automated method for coding sleep states in human infants based on respiratory rate variability.

Authors:  Joseph R Isler; Tracy Thai; Michael M Myers; William P Fifer
Journal:  Dev Psychobiol       Date:  2016-10-20       Impact factor: 3.038

Review 9.  The Visual Scoring of Sleep in Infants 0 to 2 Months of Age.

Authors:  Madeleine M Grigg-Damberger
Journal:  J Clin Sleep Med       Date:  2016-03       Impact factor: 4.062

Review 10.  A review of the effects of sleep during the first year of life on cognitive, psychomotor, and temperament development.

Authors:  Mathew Ednick; Aliza P Cohen; Gary L McPhail; Dean Beebe; Narong Simakajornboon; Raouf S Amin
Journal:  Sleep       Date:  2009-11       Impact factor: 5.849

View more