Literature DB >> 9316935

Evaluation of the ESP Culture System II for recovery of mycobacteria from blood specimens collected in isolator tubes.

C A Tholcken1, S Huang, G L Woods.   

Abstract

The reliability of the ESP Culture System II (ESP II; AccuMed International, Westlake, Ohio), a continuously monitoring, nonradiometric mycobacterial culture system, for recovery of mycobacteria from sediments of blood collected in an Isolator tube was evaluated by comparing its performance to inoculation of the sediment onto Middlebrook 7H11/7H11 selective biplates. Of 1,704 blood specimens, 73 (4.3%) were positive for mycobacteria (68 Mycobacterium avium complex and 5 M. tuberculosis). Fifty-three specimens were positive by both methods; 13 were positive by ESP II only, and 7 were positive by Middlebrook agar only (chi square = 1.8; P > 0.05). The mean times to positivity were 15.6 days for ESP II and 19.0 days for Middlebrook agar (P < 0.01). The time to detection was the same for 13 specimens; ESP II was positive first for 33, and agar plates were positive first for 7. ESP II allowed recovery of more mycobacteria (90.4% of all isolates versus 82.2% for Middlebrook agar) from sediments of blood specimens collected in Isolator tubes, and it provided significantly faster detection than did Middlebrook plates.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9316935      PMCID: PMC230038          DOI: 10.1128/jcm.35.10.2681-2682.1997

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Use of nucleic acid probes to identify mycobacteria directly from Difco ESP-Myco bottles.

Authors:  V J Labombardi; L Carter; S Massarella
Journal:  J Clin Microbiol       Date:  1997-04       Impact factor: 5.948

2.  Comparison of BACTEC 13A medium and Du Pont isolator for detection of mycobacteremia.

Authors:  F G Witebsky; J F Keiser; P S Conville; R Bryan; C H Park; R Walker; S H Siddiqi
Journal:  J Clin Microbiol       Date:  1988-08       Impact factor: 5.948

3.  Clinical evaluation of difco ESP culture system II for growth and detection of mycobacteria.

Authors:  G L Woods; G Fish; M Plaunt; T Murphy
Journal:  J Clin Microbiol       Date:  1997-01       Impact factor: 5.948

4.  Recovery of mycobacteria from blood in mycobacteria growth indicator tube and Lowenstein-Jensen slant after lysis-centrifugation.

Authors:  B A Hanna; S B Walters; S J Bonk; L J Tick
Journal:  J Clin Microbiol       Date:  1995-12       Impact factor: 5.948

5.  Evaluation of four mycobacterial blood culture media: BACTEC 13A, Isolator/BACTEC 12B, Isolator/Middlebrook agar, and a biphasic medium.

Authors:  M B Agy; C K Wallis; J J Plorde; L C Carlson; M B Coyle
Journal:  Diagn Microbiol Infect Dis       Date:  1989 Jul-Aug       Impact factor: 2.803

6.  Inhibitory effect of the Isolator blood culture system on growth of Mycobacterium avium-M. intracellulare in BACTEC 12B bottles.

Authors:  B Wasilauskas; R Morrell
Journal:  J Clin Microbiol       Date:  1994-03       Impact factor: 5.948

7.  Recommendations on prophylaxis and therapy for disseminated Mycobacterium avium complex disease in patients infected with the human immunodeficiency virus. Public Health Service Task Force on Prophylaxis and Therapy for Mycobacterium avium Complex.

Authors:  H Masur
Journal:  N Engl J Med       Date:  1993-09-16       Impact factor: 91.245

Review 8.  The Mycobacterium avium complex.

Authors:  C B Inderlied; C A Kemper; L E Bermudez
Journal:  Clin Microbiol Rev       Date:  1993-07       Impact factor: 26.132

9.  Comparison of three methods for recovery of Mycobacterium avium complex from blood specimens.

Authors:  M Salfinger; E W Stool; D Piot; L Heifets
Journal:  J Clin Microbiol       Date:  1988-06       Impact factor: 5.948

10.  Optimum recovery of Mycobacterium avium complex from blood specimens of human immunodeficiency virus-positive patients by using small volumes of isolator concentrate inoculated into BACTEC 12B bottles.

Authors:  G V Doern; J A Westerling
Journal:  J Clin Microbiol       Date:  1994-10       Impact factor: 5.948

View more
  3 in total

1.  Multicenter comparison of ESP Culture System II with BACTEC 460TB and with Lowenstein-Jensen medium for recovery of mycobacteria from different clinical specimens, including blood.

Authors:  E Tortoli; P Cichero; M G Chirillo; M R Gismondo; L Bono; G Gesu; M T Simonetti; G Volpe; G Nardi; P Marone
Journal:  J Clin Microbiol       Date:  1998-05       Impact factor: 5.948

2.  Evaluation of BACTEC MYCO/F lytic medium for recovery of mycobacteria and fungi from blood.

Authors:  R T Waite; G L Woods
Journal:  J Clin Microbiol       Date:  1998-05       Impact factor: 5.948

3.  Comparison of the BACTEC MGIT 960 and ESP culture system II for growth and detection of mycobacteria.

Authors:  N Williams-Bouyer; R Yorke; H I Lee; G L Woods
Journal:  J Clin Microbiol       Date:  2000-11       Impact factor: 5.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.