Literature DB >> 9315155

Color Doppler ultrasonographic detection of a vibrating needle system.

C D Jones1, J P McGahan, K J Clark.   

Abstract

The purpose of this study was to compare needle detection using a commercially available vibrating needle system that is used with color Doppler sonography and conventional real-time needle guidance during ultrasonographically guided intervention. Twenty-four paired (48 total) sonographically guided needle placements were performed in 22 patients for fine needle biopsy. Two patients underwent two additional needle placements at later times and, therefore, underwent a total of four needle passes each. Twenty-four of the needles were placed utilizing conventional real-time ultrasonographic guidance, and 24 were guided using a commercially available vibrating needle system. The Color Mark System was compared with standard technique for needle visualization and graded according to ease of needle visualization (improved, no change, or more difficult visualization). This was done for both needle tip and needle shaft visualization. Visualization was graded in both superficial (less than 3 cm deep) and deep structures. Overall needle tip and shaft visualization improved in 14 of 24 cases in superficial tissues and in three of 24 cases in superficial and deep tissues with the Color Mark System. The vibrating needle system also was judged to be somewhat cumbersome when used with a 22 gauge needle, as its weight tended to bend the needle shaft. The needle vibrating system may enhance needle visualization in superficial structures, but with the present design it is of limited use in deep tissues.

Entities:  

Mesh:

Year:  1997        PMID: 9315155     DOI: 10.7863/jum.1997.16.4.269

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

1.  Ultrasound-assisted musculoskeletal procedures: A practical overview of current literature.

Authors:  Nelson A Royall; Emily Farrin; David P Bahner; Stanislaw Pa Stawicki
Journal:  World J Orthop       Date:  2011-07-18

Review 2.  [How should anesthesiologists perform ultrasound examinations? Diagnostic use of ultrasound in emergency and intensive care and medicine].

Authors:  T Maecken; H Zinke; M Zenz; T Grau
Journal:  Anaesthesist       Date:  2011-03       Impact factor: 1.041

3.  Needle Tip Visibility in 3D Ultrasound Images.

Authors:  Muhammad Arif; Adriaan Moelker; Theo van Walsum
Journal:  Cardiovasc Intervent Radiol       Date:  2017-09-19       Impact factor: 2.740

4.  Localization Accuracy of Ultrasound-Actuated Needle with Color Doppler Imaging.

Authors:  Tingyi Jiang; Xinle Zhu; Yang Jiao; Xinze Li; Zhitian Shen; Yaoyao Cui
Journal:  Diagnostics (Basel)       Date:  2020-11-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.