Literature DB >> 9313595

Automatic measurement of corrected QT interval in Holter recordings: comparison of its dynamic behavior in patients after myocardial infarction with and without life-threatening arrhythmias.

E Homs1, V Martí, J offndo, P Laguna, X Viñolas, P Caminal, R Elosua, A Bayés de Luna.   

Abstract

This study was designed to determine the value of automatic corrected QT-interval measurement in Holter tapes in patients after myocardial infarction as a marker of life-threatening ventricular arrhythmias. We compared the corrected QT interval, automatically measured in 24-hour Holter recordings, in two groups of patients after myocardial infarction: group I was composed of 14 patients admitted consecutively to our hospital for documented sustained ventricular tachycardia or out-of-hospital cardiac arrest. Group II consisted of 28 patients with previous myocardial infarction with characteristics similar to those of group I, but without malignant ventricular arrhythmias in the follow-up. The global mean 24-hour corrected QT interval was longer in group I (425 +/- 20 msec) than in those patients after myocardial infarction without arrhythmias (group II) (405 +/- 17 msec; p < 0.01). Furthermore, a significant proportion of patients of group I (seven of 14) exhibited more peaks of corrected QT longer than 500 msec compared with patients of group II (two of 28; p < 0.005). A circadian rhythm of corrected QT peaks was observed in group I, having a significantly higher incidence from 11 PM to 11 AM (p < 0.05). We conclude that automatic corrected QT-interval measurement on Holter electrocardiogram is now available and feasible. Our results suggest that this is a marker for risk assessment of life-threatening ventricular arrhythmias. Large-scale trials are needed to confirm these results and to determine the predictive value of this technique for risk stratification.

Entities:  

Mesh:

Year:  1997        PMID: 9313595     DOI: 10.1016/s0002-8703(97)70122-4

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

1.  Beat-to-beat QT dynamics in healthy subjects.

Authors:  Berit T Jensen; Charlotte E Larroude; Lars P Rasmussen; Niels-Henrik Holstein-Rathlou; Michael V Hojgaard; Erik Agner; Jørgen K Kanters
Journal:  Ann Noninvasive Electrocardiol       Date:  2004-01       Impact factor: 1.468

Review 2.  QT dynamics and variability.

Authors:  Wojciech Zareba; Antoni Bayes de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-04       Impact factor: 1.468

3.  Dynamics of ventricular repolarization in patients with dilated cardiomyopathy versus healthy subjects.

Authors:  Jose Luis Alonso; Pablo Martínez; Montserrat Vallverdú; Iwona Cygankiewicz; Maria Vittoria Pitzalis; Antoni Bayés Genís; Juan Cinca; Paolo Rizzon; Pere Caminal; Wojciech Zareba; Antoni Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-04       Impact factor: 1.468

4.  Increased Beat-to-Beat Variability of T-Wave Heterogeneity Measured From Standard 12-Lead Electrocardiogram Is Associated With Sudden Cardiac Death: A Case-Control Study.

Authors:  Jenni J Hekkanen; Tuomas V Kenttä; Mira Anette E Haukilahti; Janne T Rahola; Lauri Holmström; Juha Vähätalo; Mikko P Tulppo; Antti M Kiviniemi; Lasse Pakanen; Olavi H Ukkola; M Juhani Junttila; Heikki V Huikuri; Juha S Perkiömäki
Journal:  Front Physiol       Date:  2020-08-25       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.