Literature DB >> 9310172

Evaluation of uptake and release of technetium-99m MIBI SPECT of pulmonary and mediastinal lesions.

T Komori1, I Narabayashi, R Matsui, Y Tatsu, K Sueyoshi, I Adachi, T Shimizu, R Namba, Y Nakata.   

Abstract

We evaluated the uptake and release of Tc-99m MIBI in 7 benign and 30 malignant pulmonary and mediastinal lesions. Of the 37 patients, 13 underwent surgery; malignant involvement was examined in 21 mediastinal lymph nodes. Tl-201 SPECT was also performed in 10 patients. Tc-99m MIBI SPECT studies were performed on transverse SPECT images acquired 30 minutes and 3 hours after intravenous injection of 600 MBq of Tc-99m MIBI with three gamma camera detectors (GCA-9300A). Regions of interest were set in the area of abnormal uptake of Tc-99m MIBI and in an area of normal tissue in the contralateral lung. The uptake ratio of the lesion in the contralateral normal lung was obtained on the early image (early ratio; ER) as well as the delayed image (delayed ratio; DR). The benign lesions showed significantly lower ER (1.6 +/- 0.3) and DR (1.4 +/- 0.4) than the malignant lesions (1.9 +/- 0.5 and 1.8 +/- 0.5, respectively; both p < 0.05). There was no significant difference in the retention index (RI), calculated as RI = (DR-ER)/ER x 100. The DR obtained with Tl-201 SPECT images was significantly higher than that obtained with Tc-99m MIBI SPECT (p < 0.05). For the detection of mediastinal lymph node metastases, the early images showed sensitivity, specificity, and accuracy of 85.7%, 100%, and 95.2%, respectively, for the delayed images these values were 85.7%, 92.9%, and 90.5%, respectively. These results suggest that the uptake ratio of Tc-99m MIBI is a useful index in assessing benign or malignant pulmonary and mediastinal lesions.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9310172     DOI: 10.1007/BF03164768

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  2 in total

1.  11C-acetate PET imaging of lung cancer: comparison with 18F-FDG PET and 99mTc-MIBI SPET.

Authors:  Kotaro Higashi; Yoshimichi Ueda; Ichiro Matsunari; Yuko Kodama; Ryosuke Ikeda; Katsuyuki Miura; Suzuka Taki; Takahiro Higuchi; Hisao Tonami; Itaru Yamamoto
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-22       Impact factor: 9.236

2.  The clinical usefulness of (99m)Tc-Tetrofosmin scintigraphy in the diagnosis of lung neoplasmas and mediastinal lymphoid node involvement.

Authors:  Daijuan Huang; Feng Zhao; Yongxue Zhang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2008-10-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.