Literature DB >> 9310036

Improved fixation of porous-coated versus grit-blasted surface texture of hydroxyapatite-coated implants in dogs.

S Overgaard1, M Lind, O Rahbek, C Bünger, K Søballe.   

Abstract

We inserted, in 8 dogs, implants with either porous-coated or grit-blasted titanium surface and coated with hydroxyapatite (HA) into trabecular bone in the proximal humerus, using a 1 mm gap model. After 25 weeks, push-out tests showed that energy absorption for porous-coated implants was twice that of grit-blasted implants, whereas shear stiffness was reduced by one fifth, indicating a stronger fixation of porous-coated implants. Macroscopically, all grit-blasted implants had delamination of the HA coating, whereas porous implants failed mostly at the HA-tissue interface. Porous-coated implants had 47% bone ingrowth and grit-blasted implants 70% (p = 0.02), however, no difference in absolute surface area was found. Part of the HA coating was resorbed during the implantation period as regards volume and thickness. HA coverage was more reduced on porous-coated than on grit-blasted implants (p = 0.01). No foreign-body reaction or osteolysis was seen. An important finding was that one fifth of the surface with complete resorption of HA coating was replaced by newly formed bone.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9310036     DOI: 10.3109/17453679708996173

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  7 in total

1.  Partial weightbearing is not necessary after cementless total hip arthroplasty: a two-year prospective randomized study on 100 patients.

Authors:  Max Markmiller; Thomas Weiss; Peter Kreuz; Axel Rüter; Gerhard Konrad
Journal:  Int Orthop       Date:  2010-07-11       Impact factor: 3.075

2.  Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses.

Authors:  Alphons J Tonino; Bart C H van der Wal; Ide C Heyligers; Bernd Grimm
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

3.  A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems.

Authors:  Berte Grimsmo Bøe; Stephan M Röhrl; Tore Heier; Finnur Snorrason; Lars Nordsletten
Journal:  Acta Orthop       Date:  2010-12-29       Impact factor: 3.717

4.  Cementless hydroxyapatite coated hip prostheses.

Authors:  Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Gracia
Journal:  Biomed Res Int       Date:  2015-02-23       Impact factor: 3.411

5.  Coating of titanium with hydroxyapatite leads to decreased bone formation: A study in rabbits.

Authors:  B G Bøe; R Ø Støen; L B Solberg; F P Reinholt; J E Ellingsen; L Nordsletten
Journal:  Bone Joint Res       Date:  2012-06-01       Impact factor: 5.853

6.  Migration analysis of a metaphyseal anchored short-stem hip prosthesis.

Authors:  Florian Schmidutz; Thomas Graf; Farhad Mazoochian; Andreas Fottner; Andrea Bauer-Melnyk; Volkmar Jansson
Journal:  Acta Orthop       Date:  2012-08       Impact factor: 3.717

7.  Assessment of activated porous granules on implant fixation and early bone formation in sheep.

Authors:  Ming Ding; Susan S Henriksen; Naseem Theilgaard; Søren Overgaard
Journal:  J Orthop Translat       Date:  2015-10-29       Impact factor: 5.191

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.