Literature DB >> 9302875

An automated MALDI mass spectrometry approach for optimizing cyclosporin extraction and quantitation.

J Wu1, K Chatman, K Harris, G Siuzdak.   

Abstract

A combinatorial extraction method and an automated matrix-assisted laser desorption/ionization (MALDI) mass spectrometry procedure were used to improve the clinical analysis of the immunosuppressant drug cyclosporin A. Cyclosporin extracts from whole blood were analyzed by MALDI and electrospray ionization (ESI) mass spectrometry, allowing for their identification and quantification. Due to limitations associated with the current multistep cyclosporin extraction procedure from whole blood, a combinatorial approach was devised to optimize this extraction. Optimization was performed by generating an array of solvent systems to be used for extraction from blood, and an automated analysis was carried out on a MALDI mass spectrometer to identify successful extractions. The first generation of experiments revealed four binary solvent systems to be effective for cyclosporin extraction (hexane/EtOH, ACN/H2O, ACN/MeOH, and hexane/CHCl3). A new array based on these solvent systems was generated, and a second iteration of these experiments was then performed. In the second generation of experiments, hexane/CHCl3 (70:30) was found to provide the most effective single-step extraction of these solvent systems for cyclosporin and its metabolites. The limits of detection were determined to be 15 ng/mL in whole blood for ESI/MS and MALDI-MS and could also be used for identifying major drug metabolites. In addition to applying this combinatorial approach to extraction procedures, this experimental design could easily be extended to examine other approaches, such as optimizing chemical reactions and screening inhibitors in enzymatic reactions.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9302875     DOI: 10.1021/ac970276y

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Practical quantitative biomedical applications of MALDI-TOF mass spectrometry.

Authors:  Martin Bucknall; Kim Y C Fung; Mark W Duncan
Journal:  J Am Soc Mass Spectrom       Date:  2002-09       Impact factor: 3.109

Review 2.  Quantitative matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Mark W Duncan; Heinrich Roder; Stephen W Hunsucker
Journal:  Brief Funct Genomic Proteomic       Date:  2008-09

3.  Quantification of saquinavir from lysates of peripheral blood mononuclear cells using microarrays and standard MALDI-TOF-MS.

Authors:  Martin Pabst; Stephan Rupert Fagerer; Rudolf Köhling; Klaus Eyer; Jasmin Krismer; Konstantins Jefimovs; Alfredo Jesus Ibáñez; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2014-04-08       Impact factor: 3.109

4.  Quantitative analysis of technical polymer mixtures by matrix assisted laser desorption/ionization time of flight mass spectrometry.

Authors:  Wenyan Yan; Joseph A Gardella; Troy D Wood
Journal:  J Am Soc Mass Spectrom       Date:  2002-08       Impact factor: 3.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.