Literature DB >> 9301391

Plasma dilution and the rate of infusion of Ringer's solution.

R G Hahn1, C Svensén.   

Abstract

Changes in the volume of the fluid space expanded by i.v. infusion of Ringer's acetate solution have been analysed recently using mathematical models. Data obtained by such analyses allow simulation of the dilution of the plasma volume during infusion of the solution at different rates. To obtain basic kinetic data for such simulations, the plasma dilution-time curves were measured during and after i.v. infusion of Ringer's solution 25 ml kg-1 over 30 min in 15 healthy male volunteers (mean age 31 yr) and over 30, 45 and 80 min in six females (mean age 32 yr). Based on these experiments, nomograms were constructed from which the rate of infusion of Ringer's solution and the infusion time required to obtain a defined plasma dilution in both males and females can be estimated together with the infusion rate needed to maintain the dilution at the level reached.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9301391     DOI: 10.1093/bja/79.1.64

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  8 in total

1.  The Effect of Routine Maintenance Intravenous Therapy on Hemoglobin Concentration and Hematocrit during Anesthesia in Adults.

Authors:  Seyed Masoud Lahsaee; Sina Ghaffaripour; Hossein Hejr
Journal:  Bull Emerg Trauma       Date:  2013-07

2.  Effects of high-volume, rapid-fluid therapy on cardiovascular function and hematological values during isoflurane-induced hypotension in healthy dogs.

Authors:  Alexander Valverde; Giacomo Gianotti; Eva Rioja-Garcia; Amanda Hathway
Journal:  Can J Vet Res       Date:  2012-04       Impact factor: 1.310

3.  Development of an Al-load-cell-based wireless ringer's solution monitoring and alarm system: insight into vibrational error correction.

Authors:  Hyun Seok Moon; Eue-Soon Jang
Journal:  Biomed Eng Lett       Date:  2019-03-29

4.  Effects of rapid fluid infusion on hemoglobin concentration: a systematic review and meta-analysis.

Authors:  Armin A Quispe-Cornejo; Ana L Alves da Cunha; Hassane Njimi; Wasineenart Mongkolpun; Ana L Valle-Martins; Mónica Arébalo-López; Jacques Creteur; Jean-Louis Vincent
Journal:  Crit Care       Date:  2022-10-23       Impact factor: 19.334

5.  Crystalloid Coload Reduced the Incidence of Hypotension in Spinal Anesthesia for Cesarean Delivery, When Compared to Crystalloid Preload: A Meta-Analysis.

Authors:  Hai-Fang Ni; Hua-Yue Liu; Juan Zhang; Ke Peng; Fu-Hai Ji
Journal:  Biomed Res Int       Date:  2017-12-17       Impact factor: 3.411

6.  Iatrogenic hemodilution: a possible cause for avoidable blood transfusions?

Authors:  Azriel Perel
Journal:  Crit Care       Date:  2017-11-25       Impact factor: 9.097

7.  The relationship between the decrease in haemoglobin concentration and the volume of fluids administered during resuscitation from septic shock may not be so "weak".

Authors:  Azriel Perel
Journal:  Crit Care       Date:  2018-09-20       Impact factor: 9.097

Review 8.  Understanding Volume Kinetics: The Role of Pharmacokinetic Modeling and Analysis in Fluid Therapy.

Authors:  Xiu Ting Yiew; Shane W Bateman; Robert G Hahn; Alexa M E Bersenas; William W Muir
Journal:  Front Vet Sci       Date:  2020-11-20
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.