Comparison of B-mode, M-mode and echo-tracking methods for measurement of the arterial distension waveform.

R W Stadler1, J A Taylor, R S Lees.   

Abstract

Measurements of arterial diameter throughout the cardiac cycle (i.e., the arterial distension waveform) are conducted increasingly to study mechanical properties of the arterial wall and changes associated with disease. The distension waveform of peripheral arteries can be measured noninvasively via ultrasonic echo tracking. M-mode imaging, and B-mode imaging. Of these, echo tracking is the most popular method because of its single micrometer resolution during continuous measurements under ideal conditions. However, high resolution within continuous measurements does not imply high reproducibility between measurements. Therefore, we compared repeated measurements of the amplitude of common carotid artery distension in 26 subjects, obtained sequentially in random order by: 1. Off-line echo tracking of digitized radiofrequency ultrasound; 2. M-mode imaging with automated edge detection; and 3. 30-Hz B-mode imaging with automated edge detection and model-based diameter estimation. In each case, the transducer was hand-held and was removed from the neck between repeated measurements. The amplitude of arterial distension was estimated from the serial diameter measurements by maximum likelihood (ML) estimation, by least-squares fit of a Fourier series model, and by application of a cubic smoothing spline. Within continuous measurements, the standard deviation of the ML distension amplitude for neighboring cardiac cycles was significantly smaller (p > 0.05) with echo-tracking (0.023 mm) than with the B-mode (0.036 mm) or M-mode (0.074 mm) methods. However, between discontinuous measurements on the same subject, the standard deviation of the ML distension amplitude was similar for the echo-tracking (0.076 mm) and B-mode (0.073 mm) methods. The Fourier series model and the cubic smoothing spline slightly reduced the standard deviation of the B-mode and M-mode distension amplitudes, but also reduced the mean amplitude estimate. On the basis of this relative comparison of methods, we conclude that, although echo tracking offers high resolution for continuous measurements, the reproducibility of discontinuous measurements of carotid artery distension is no better with echo tracking than can be obtained from 30-Hz B-mode images.

Mesh:

Year:  1997        PMID: 9300992     DOI: 10.1016/s0301-5629(97)00074-4

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  11 in total

Review 1.  Developments in cardiovascular ultrasound. Part 2: Arterial applications.

Authors:  P R Hoskins; P J Fish; W N McDicken; C Moran
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

2.  Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound.

Authors:  Theodore W Cary; Courtney B Reamer; Laith R Sultan; Emile R Mohler; Chandra M Sehgal
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

3.  Segmental analysis of carotid arterial strain using speckle-tracking.

Authors:  Eric Y Yang; Hisham Dokainish; Salim S Virani; Arunima Misra; Allison M Pritchett; Nasser Lakkis; Gerd Brunner; Jaromir Bobek; Marti L McCulloch; Craig J Hartley; Christie M Ballantyne; Sherif F Nagueh; Vijay Nambi
Journal:  J Am Soc Echocardiogr       Date:  2011-09-09       Impact factor: 5.251

4.  Circulating calcification inhibitors and vascular properties in children after renal transplantation.

Authors:  Marieke J H van Summeren; Jeroen M Hameleers; Leon J Schurgers; Arnold P G Hoeks; Cuno S P M Uiterwaal; Thilo Krüger; Cees Vermeer; Wietse Kuis; Marc R Lilien
Journal:  Pediatr Nephrol       Date:  2008-06       Impact factor: 3.714

5.  In vivo comparison of atherosclerotic plaque progression with vessel wall strain and blood flow velocity in apoE(-/-) mice with MR microscopy at 17.6 T.

Authors:  Volker Herold; Jeremy Wellen; Christian H Ziener; Thomas Weber; Karl-Heinz Hiller; Peter Nordbeck; Eberhard Rommel; Axel Haase; Wolfgang R Bauer; Peter M Jakob; Susanta K Sarkar
Journal:  MAGMA       Date:  2009-01-20       Impact factor: 2.310

6.  Non-invasive assessment of arterial distension waveforms using gradient-based hough transform and power Doppler ultrasound imaging.

Authors:  S M Wu; Y W Shau; F C Chong; F J Hsieh
Journal:  Med Biol Eng Comput       Date:  2001-11       Impact factor: 3.079

7.  Regional in vivo transit time measurements of aortic pulse wave velocity in mice with high-field CMR at 17.6 Tesla.

Authors:  Marco Parczyk; Volker Herold; Gert Klug; Wolfgang R Bauer; Eberhard Rommel; Peter M Jakob
Journal:  J Cardiovasc Magn Reson       Date:  2010-12-06       Impact factor: 5.364

8.  Ultrasound evaluation of effect of different degree of wrist extension on radial artery dimension at the wrist joint.

Authors:  Venkatesh Selvaraj; Faiza Sulaiman Buhari
Journal:  Ann Card Anaesth       Date:  2016 Jan-Mar

9.  Assessment of the endothelial function with changed volume of brachial artery by menstrual cycle.

Authors:  Shing-Hong Liu; Jia-Jung Wang; Da-Chuan Cheng; Chun-Hung Su; Tzu-Hsin Lin
Journal:  Biomed Eng Online       Date:  2016-09-06       Impact factor: 2.819

10.  Tissue Doppler imaging of carotid plaque wall motion: a pilot study.

Authors:  Kumar V Ramnarine; Tim Hartshorne; Yvonne Sensier; May Naylor; Joanne Walker; A Ross Naylor; Ronney B Panerai; David H Evans
Journal:  Cardiovasc Ultrasound       Date:  2003-12-19       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.