Literature DB >> 9300295

T wave alternans during exercise and atrial pacing in humans.

S H Hohnloser1, T Klingenheben, M Zabel, Y G Li, P Albrecht, R J Cohen.   

Abstract

INTRODUCTION: Evidence is accumulating that microvolt T wave alternans (TWA) is a marker of increased risk for ventricular tachyarrhythmias. Initially, atrial pacing was used to elevate heart rate and elicit TWA. More recently, a noninvasive approach has been developed that elevates heart rate using exercise. METHODS AND
RESULTS: In 30 consecutive patients with a history of ventricular tachyarrhythmias, the spectral method was used to detect TWA during both atrial pacing and submaximal exercise testing. The concordance rate for the presence or absence of TWA using the two measurement methods was 84%. There was a patient-specific heart rate threshold for the detection of TWA that averaged 100 +/- 14 beats/min during exercise compared with 97 +/- 9 beats/min during right atrial pacing (P = NS). Beyond this threshold, there was a significant and comparable increase in level of TWA with decreasing pacing cycle length and increasing exercise heart rates.
CONCLUSIONS: The present study is the first to demonstrate that microvolt TWA can be assessed reliably and noninvasively during exercise stress. There is a patient-specific heart rate threshold beyond which TWA continues to increase with increasing heart rates. Heart rate thresholds for the onset of TWA measured during atrial pacing and exercise stress were comparable, indicating that heart rate alone appears to be the main factor of determining the onset of TWA during submaximal exercise stress.

Entities:  

Keywords:  NASA Discipline Regulatory Physiology; Non-NASA Center

Mesh:

Year:  1997        PMID: 9300295     DOI: 10.1111/j.1540-8167.1997.tb00621.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  21 in total

Review 1.  T-wave alternans and arrhythmia risk stratification.

Authors:  N El-Sherif; G Turitto; R P Pedalino; D Robotis
Journal:  Ann Noninvasive Electrocardiol       Date:  2001-10       Impact factor: 1.468

2.  Is T-wave alternans testing feasible in candidates for prophylactic implantable defibrillators?

Authors:  K Kraaier; T McCracken; J van der Palen; A A M Wilde; M F Scholten
Journal:  Neth Heart J       Date:  2011-01       Impact factor: 2.380

3.  Action potential duration dispersion and alternans in simulated heterogeneous cardiac tissue with a structural barrier.

Authors:  Trine Krogh-Madsen; David J Christini
Journal:  Biophys J       Date:  2006-11-17       Impact factor: 4.033

4.  Chaos for cardiac arrhythmias through a one-dimensional modulation equation for alternans.

Authors:  Shu Dai; David G Schaeffer
Journal:  Chaos       Date:  2010-06       Impact factor: 3.642

Review 5.  Mental Stress and Ventricular Arrhythmias.

Authors:  Rachel Lampert
Journal:  Curr Cardiol Rep       Date:  2016-12       Impact factor: 2.931

6.  Predicting the recurrence of ventricular tachyarrhythmias from T-wave alternans assessed on antiarrhythmic pharmacotherapy: a prospective study in patients with dilated cardiomyopathy.

Authors:  K Sakabe; T Ikeda; T Sakata; A Kawase; K Kumagai; N Tezuka; M Takami; T Nakae; M Noro; Y Enjoji; K Sugi; T Yamaguchi
Journal:  Ann Noninvasive Electrocardiol       Date:  2001-07       Impact factor: 1.468

Review 7.  T-wave alternans for risk stratification and prevention of sudden cardiac death.

Authors:  Etienne J Pruvot; David S Rosenbaum
Journal:  Curr Cardiol Rep       Date:  2003-09       Impact factor: 2.931

Review 8.  Anger and ventricular arrhythmias.

Authors:  Rachel Lampert
Journal:  Curr Opin Cardiol       Date:  2010-01       Impact factor: 2.161

9.  T-wave alternans and ST depression assessment identifies low risk individuals with ischemic cardiomyopathy in the absence of left ventricular hypertrophy.

Authors:  Daniel J Friedman; Seth R Bender; Steven M Markowitz; Bruce B Lerman; Peter M Okin
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-05-03       Impact factor: 1.468

10.  ECG signatures of psychological stress.

Authors:  Rachel Lampert
Journal:  J Electrocardiol       Date:  2015-08-18       Impact factor: 1.438

View more