Bond strengths of maxillary anterior base metal resin-bonded retainers with different thicknesses.

A A Ibrahim1, D Byrne, D L Hussey, N Claffey.   

Abstract

PURPOSE: This study evaluated the effect of three different thicknesses of base metal resin-bonded retainers on retention/resistance.
MATERIAL AND METHODS: Three ivorine teeth, a central incisor, lateral incisor, and canine, were prepared to receive resin bonded retainers. Fifteen metal replicas of prepared teeth were made (five for each tooth morphotype). A total of 45 metal retainers were cast in three different thicknesses, 0.3, 0.5, and 0.7 mm, with 15 for each thickness. Retainers were cemented to metal die replicas with Panavia EX luting agent. After 24 hours, forces to dislodge the retainers were applied at 45 degrees to the vertical mesiodistal plane at the proximolingual line angle.
RESULTS: An increase in thicknesses resulted in elevation of dislodging forces that were almost linear for the three thicknesses of canine retainers. The central incisor exhibited the greatest increase in resistance to dislodgment between retainers that were 0.3 and 0.5 mm thick, whereas increased thickness for the lateral incisor retainer resulted in minimal or no benefit.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9297645     DOI: 10.1016/s0022-3913(97)70027-1

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  2 in total

1.  Attitude and awareness of dentist towards resin bonded bridges in Saudi Arabia.

Authors:  Fahim Ahmed Vohra; Muhammed Ayedh Al-Qahtani
Journal:  Saudi Dent J       Date:  2014-05-05

2.  Evaluation of the effects of different groove length and thickness of the retainers on the retention of maxillary anterior base metal resin bonded retainers-an in vitro study.

Authors:  Anoop Nair; K M Regish; N P Patil; D R Prithviraj
Journal:  J Clin Exp Dent       Date:  2012-04-01