Literature DB >> 9293509

Long-term precision of glomerular filtration rate measurements using 51Cr-EDTA plasma clearance.

G M Blake1, D Roe, C R Lazarus.   

Abstract

The long-term precision of chromium-51 ethylenediamine tetraacetic acid (51Cr-EDTA) measurements of glomerular filtration rate (GFR) was evaluated in a retrospective study of data obtained over a 12 year period. Each GFR measurement was derived from plasma samples taken at 2, 3 and 4 h following injection of 3 MBq 51Cr-EDTA. The records of 7507 patients were reviewed, from which 55 subjects were identified as having had studies on 10 or more occasions. The mean number of studies per patient was 12.9 (range 10-23) over a mean period of 9.4 years (range 4.3-11.8 years). Plots of GFR, clearance half-life, (T1/2) and volume of distribution (VD) were drawn for each patient and used to identify subjects showing linear changes with time that could be fitted using linear regression. Each residual was expressed as a percentage of the expected value calculated from the regression line and all the residuals combined to give histograms for GFR, T1/2 and VD. Each histogram was fitted with a normal distribution between the -3 S.D. and +3 S.D. limits using weighted least squares. Final results for the coefficient of variation were: GFR 9.8%, T1/2 6.7%, VD 9.4%. The precision errors were used to calculate the smallest statistically significant change measurable by the 51Cr-EDTA technique. With 10% significance and 80% power, the smallest measureable change was 30% for GFR and 20% for T1/2. Unless there are clinical grounds for thinking that a patient's volume of distribution has changed, T1/2 is the optimal parameter for identifying real changes in renal function.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9293509     DOI: 10.1097/00006231-199708000-00012

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  3 in total

1.  Comparison of estimated GFR and measured GFR in prospective living kidney donors.

Authors:  Thakshyanee Bhuvanakrishna; Glen M Blake; Rachel Hilton; Lisa Burnapp; Christopher Sibley-Allen; David Goldsmith
Journal:  Int Urol Nephrol       Date:  2014-11-06       Impact factor: 2.370

2.  Reliability of transcutaneous measurement of renal function in various strains of conscious mice.

Authors:  Daniel Schock-Kusch; Stefania Geraci; Esther Ermeling; Yury Shulhevich; Carsten Sticht; Juergen Hesser; Dzmitry Stsepankou; Sabine Neudecker; Johannes Pill; Roland Schmitt; Anette Melk
Journal:  PLoS One       Date:  2013-08-19       Impact factor: 3.240

3.  The eGFR-C study: accuracy of glomerular filtration rate (GFR) estimation using creatinine and cystatin C and albuminuria for monitoring disease progression in patients with stage 3 chronic kidney disease--prospective longitudinal study in a multiethnic population.

Authors:  Edmund J Lamb; Elizabeth A Brettell; Paul Cockwell; Neil Dalton; Jon J Deeks; Kevin Harris; Tracy Higgins; Philip A Kalra; Kamlesh Khunti; Fiona Loud; Ryan S Ottridge; Claire C Sharpe; Alice J Sitch; Paul E Stevens; Andrew J Sutton; Maarten W Taal
Journal:  BMC Nephrol       Date:  2014-01-14       Impact factor: 2.388

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.