Literature DB >> 9291397

Stereotactic breast biopsy: a surgical series.

A J Stolier1.   

Abstract

BACKGROUND: Stereotactic core needle biopsy (SCNB) is increasing in popularity and is currently being performed by both radiologists and surgeons. It has been shown to be accurate and cost effective, but the appropriate use of SCNB in the probably benign mammographic lesion has not been determined. Nor has it been determined whether a learning curve affects performance of the procedure. STUDY
DESIGN: The records of all patients undergoing SCNB by the author from August 1993 through May 1996 were reviewed. Two hundred forty-two patients underwent 244 procedures. Indications for biopsy, results, and complications were examined.
RESULTS: Probably benign mass was the most common indication for biopsy (45%), and microcalcifications were the indication for biopsy in 24%. A diagnosis of cancer was made in 11.1%. Patients with microcalcifications and probably benign masses were diagnosed with cancer in 18.4 and 1.8%, respectively. Three of eight patients undergoing open biopsy for atypical hyperplasia were diagnosed with cancer. Accuracy rate for the entire series was 97.7%. The effect of operator experience on the indication for SCNB was studied. As experience increased from the first to the last third of the study, microcalcifications as an indication increased from 23.5-37.5%. During this same time period, "probably benign" mass decreased from 53.1-32.5%.
CONCLUSION: This study demonstrates that accuracy of this surgical series is comparable to other published series. Biopsies for more difficult lesions were noted to increase as operator experience increased. It was likely that this "learning curve" was owing to improvements in technique and an increased confidence in the accuracy of the procedure. With an incidence of cancer of less than 2% in patients with a probably benign mass, interval mammography represents for many, a cost-effective alternative.

Entities:  

Mesh:

Year:  1997        PMID: 9291397     DOI: 10.1016/s1072-7515(97)00031-8

Source DB:  PubMed          Journal:  J Am Coll Surg        ISSN: 1072-7515            Impact factor:   6.113


  2 in total

1.  Must breast care delivery models from resource-rich environments be applied to resource-limited environments?

Authors:  Justus Apffelstaedt; John P Mouton; Karin Baatjes
Journal:  World J Surg       Date:  2010-11       Impact factor: 3.352

2.  A comparison of diagnostic performance of vacuum-assisted biopsy and core needle biopsy for breast microcalcification: a systematic review and meta-analysis.

Authors:  Xu Chen Huang; Xu Hua Hu; Xiao Ran Wang; Chao Xi Zhou; Fei Fei Wang; Shan Yang; Gui Ying Wang
Journal:  Ir J Med Sci       Date:  2018-03-16       Impact factor: 1.568

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.