Literature DB >> 9290574

Assessment of the accuracy of indirect blood pressure measurements.

H Ochiai1, N Miyazaki, T Miyata, A Mitake, O Tochikubo, M Ishii.   

Abstract

This study assessed the accuracy of indirect blood pressure (BP) measurements by simultaneously performing three kinds of indirect BP measurement on the left arm (auscultatory, microphone and oscillometric methods) and a direct BP measurement on the left arm. The subjects were 34 hospitalized patients, ranging in age from 18 to 73 years (average 47.5 years). Highly significant correlations in systolic or diastolic BP between a given pair of the three indirect methods. The indirect methods underestimated systolic BP and overestimated diastolic BP compared with the direct method, with differences of -12.2 +/- 10.5/+4.6 +/- 7.6 (systolic/diastolic BP) with the oscillometric method, -8.1 +/- 9.7/+1.2 +/- 8.9 with the microphone method and -10.6 +/- 8.1/+3.7 +/- 6.5 mmHg with the auscultatory method. The difference in systolic BP between the auscultatory and direct methods was greater and the difference in diastolic BP was smaller in subjects older than 50 years than in those aged 50 years or less (p < 0.001 for systolic BP, p < 0.05 for diastolic BP). The auscultatory method revealed greater systolic BP in subjects with increased carotid arterial wall stiffness assessed by echoarteriography. Thus, it is concluded that there are inherent differences in BP between the indirect and direct methods which can be attributed to the changes in arterial wall physical properties partly due to aging.

Entities:  

Mesh:

Year:  1997        PMID: 9290574     DOI: 10.1536/ihj.38.393

Source DB:  PubMed          Journal:  Jpn Heart J        ISSN: 0021-4868


  5 in total

1.  Central blood pressure estimation by using N-point moving average method in the brachial pulse wave.

Authors:  Rie Sugawara; Shigeo Horinaka; Hiroshi Yagi; Kimihiko Ishimura; Takeharu Honda
Journal:  Hypertens Res       Date:  2015-02-19       Impact factor: 3.872

2.  A Meta-analysis to Determine the Validity of Taking Blood Pressure Using the Indirect Cuff Method.

Authors:  Scott J Dankel; Minsoo Kang; Takashi Abe; Jeremy P Loenneke
Journal:  Curr Hypertens Rep       Date:  2019-02-07       Impact factor: 5.369

3.  Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysis.

Authors:  Christopher E Clark; Sinead T J McDonagh; Richard J McManus
Journal:  J Hum Hypertens       Date:  2019-01-10       Impact factor: 3.012

Review 4.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

5.  Differential response of central blood pressure to isometric and isotonic exercises.

Authors:  Satoru Tanaka; Tomonori Sugiura; Sumiyo Yamashita; Yasuaki Dohi; Genjiro Kimura; Nobuyuki Ohte
Journal:  Sci Rep       Date:  2014-06-25       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.